Jøtul F 620 B Operating Instructions Manual
Jøtul F 620 B Operating Instructions Manual

Jøtul F 620 B Operating Instructions Manual

Wood stove
Table of Contents

Advertisement

Quick Links

Jøtul F 620 B, P, LB, B HT
OPERATING INSTRUCTIONS
Since 1853
Jøtul AS,
P.O. Box 1411
N-1602 Fredrikstad,
Norway
intl.jotul.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul F 620 B

  • Page 1 Jøtul F 620 B, P, LB, B HT OPERATING INSTRUCTIONS Since 1853 Jøtul AS, P.O. Box 1411 N-1602 Fredrikstad, Norway intl.jotul.com...
  • Page 2 Attention! Use this approval label when the stoves has been installed (only for UK). Cut off the bottom part and replace the label already attached with this one. It is important that the lot + pin number is viewable. Note: An approved CO monitor should be installed in the same room as the appliance.
  • Page 3: Table Of Contents

    OPERATIONAL PROBLEMS INSTALLATION JØTUL F 620 B - OUTSIDE AIR TROUBLESHOOTING ......44 BOTTOM ..............14 INSTALLATION JØTUL F 620 B - OUTSIDE AIR REAR19 OPTIONAL EXTRAS ......44 INSTALLATION JØTUL F 620 P - OUTSIDE AIR BOTTOM ..............22 JØTUL F 620 Cast Iron side Le BP ......44 INSTALLATION JØTUL F 620 P - OUTSIDE AIR REAR26...
  • Page 4: Relationship To The Authorities

    TECHNICAL DATA RELATIONSHIP TO THE AUTHORITIES Material Cast iron Surface treatment Black paint The installa on of a fi replace must be carried out in compliance Type of fuel Wood with na onal laws and regula ons. Max. log length 60 cm The process of installing the product must be in compliance with all Recommended log length...
  • Page 5: Safety

    SAFETY To guarantee op mal performance and safety, Jøtul recommends that its stoves are fi ed by a qualifi ed installer (see The func on of a fl oor plate is to protect the fl oor and fl ammable www.jotul.com for a complete list of dealers). materials against embers.
  • Page 6: Jøtul F 620 B: Dimensional Diagram And Assembly Distances

    JØTUL F 620 B: DIMENSIONAL DIAGRAM AND ASSEMBLY DISTANCES JØTUL F 620 B...
  • Page 7: Jøtul F 620 P: Dimensional Diagram And Assembly Distances

    JØTUL F 620 P: DIMENSIONAL DIAGRAM AND ASSEMBLY DISTANCES JØTUL F 620 P...
  • Page 8: Jøtul F 620 Lb: Dimensional Diagram And Assembly Distances

    JØTUL F 620 LB: DIMENSIONAL DIAGRAM AND ASSEMBLY DISTANCES JØTUL F 620 LB...
  • Page 9: Jøtul F 620: Minimum Distance To Combustible Wall

    JØTUL F 620: MINIMUM DISTANCE TO COMBUSTIBLE WALL F 620: MIN. DISTANCE TO COMBUSTIBLE WALL F 620: MIN. DISTANCE TO COMBUSTIBLE WALL F 620: MIN. DISTANCE TO COMBUSTIBLE WALL...
  • Page 10: Jøtul F 620: Minimum Distance To Combustible Wall Protected By Approved Fireproof Wall

    JØTUL F 620: MINIMUM DISTANCE TO COMBUSTIBLE WALL PROTECTED BY APPROVED FIREPROOF WALL...
  • Page 11: Installation

    INSTALLATION CHIMNEY AND FLUE PIPE • The fi replace can be connected to a chimney and fl ue pipe approved for solid fuel fi replaces with fl ue gas temperatures as specifi ed in “Technical Data”. If a steel chimney is used, this must be marked with T 400 and G for soot fi re tes ng. •...
  • Page 12: Prior To Installation

    PRIOR TO INSTALLATION • Before installing the fi replace, check it carefully for any signs of damage • The product is heavy! Ask someone to help you when posi oning and installing it. We recommend using a li ing device. •...
  • Page 13: Dismantling Parts

    DISMANTLING PARTS Log retainer Inner bo om grate Inner bo om Rear burn plate Baffl e plate Exhaust defl ector PRESS HERE TO NAVIGATE TO DISMANTLING INTERNAL PARTS...
  • Page 14: Installation Jøtul F 620 B - Outside Air Bottom

    INSTALLATION JØTUL F 620 B - OUTSIDE AIR BOTTOM F 620 Base...
  • Page 15 INSTALLATION JØTUL F 620 B - OUTSIDE AIR BOTTOM F 620 Base...
  • Page 16 INSTALLATION JØTUL F 620 B - OUTSIDE AIR BOTTOM F 620 Base...
  • Page 17 INSTALLATION JØTUL F 620 B - OUTSIDE AIR BOTTOM F 620 Base...
  • Page 18 INSTALLATION JØTUL F 620 B - OUTSIDE AIR BOTTOM F 620 Base Min. 100mm...
  • Page 19: Installation Jøtul F 620 B - Outside Air Rear19

    INSTALLATION JØTUL F 620 B - OUTSIDE AIR REAR F 620 Base...
  • Page 20 INSTALLATION JØTUL F 620 B - OUTSIDE AIR REAR F 620 Base...
  • Page 21 INSTALLATION JØTUL F 620 B - OUTSIDE AIR REAR F 620 Base...
  • Page 22: Installation Jøtul F 620 P - Outside Air Bottom

    INSTALLATION JØTUL F 620 P - OUTSIDE AIR BOTTOM F 620 Pedestal...
  • Page 23 INSTALLATION JØTUL F 620 P - OUTSIDE AIR BOTTOM F 620 Pedestal...
  • Page 24 INSTALLATION JØTUL F 620 P - OUTSIDE AIR BOTTOM F 620 Pedestal...
  • Page 25 INSTALLATION JØTUL F 620 P - OUTSIDE AIR BOTTOM F 620 Pedestal Min. 100...
  • Page 26: Installation Jøtul F 620 P - Outside Air Rear26

    INSTALLATION JØTUL F 620 P - OUTSIDE AIR REAR F 620 Pedestal...
  • Page 27 INSTALLATION JØTUL F 620 P - OUTSIDE AIR REAR F 620 Pedestal...
  • Page 28 INSTALLATION JØTUL F 620 P - OUTSIDE AIR REAR F 620 Pedestal...
  • Page 29 INSTALLATION JØTUL F 620 P - OUTSIDE AIR REAR F 620 Pedestal...
  • Page 30: Installation Jøtul F 620 Lb - Without Outside Air Connection

    INSTALLATION JØTUL F 620 LB - WITHOUT OUTSIDE AIR CONNECTION F 620 Low Base...
  • Page 31: Installation Jøtul F 620 Lb - Outside Air Bottom

    INSTALLATION JØTUL F 620 LB - OUTSIDE AIR BOTTOM F 620 Low Base...
  • Page 32: Installation Jøtul F 620 Lb - Outside Air Bottom

    INSTALLATION JØTUL F 620 LB - OUTSIDE AIR BOTTOM F 620 Low Base Min. 100...
  • Page 33: Installation Jøtul F 620 Lb - Outside Air Rear

    INSTALLATION JØTUL F 620 LB - OUTSIDE AIR REAR F 620 Low Base...
  • Page 34 INSTALLATION JØTUL F 620 LB - OUTSIDE AIR REAR F 620 Low Base...
  • Page 35: Dismantling Internal Parts

    DISMANTLING INTERNAL PARTS...
  • Page 36 DISMANTLING INTERNAL PARTS...
  • Page 37: Installation Of Internal Parts

    INSTALLATION OF INTERNAL PARTS...
  • Page 38 INSTALLATION OF INTERNAL PARTS...
  • Page 39 INSTALLATION OF INTERNAL PARTS...
  • Page 40: Daily Use

    DAILY USE ODOURS WHEN USING THE FIREPLACE Fig. 2 FOR THE FIRST TIME When the fi replace is used for the fi rst me, it may give off a slight smell. This is because the paint on the outside is drying. You should open some windows to ensure the room is ven lated.
  • Page 41 Fig. 3a Through an outside wall Fig. 3d Indirectly through an outside wall Fig. 3b Through the fl oor and ground Hea ng advice Logs that have been stored outdoors or in a cold room should be brought indoors approx. 24 hours before use to bring them up to room temperature.
  • Page 42: Wood Consumption

    WOOD CONSUMPTION The effi ciency of the Jøtul F 620 gives it a nominal heat output of approx. 8.5 kW. Wood consump on, at nominal heat output: Approx. 2.64 kg/t. The size of the logs should be: Recommended length: 20 - 33 Diameter: Approx.
  • Page 43: Maintenance

    MAINTENANCE CLEANING THE GLASS Jøtul’s fi replaces are fi ed with air washing of the glass. Via the air vent, air is defl ected down along the inside of the glass, reducing the accumula on of soot deposits. There will always be some soot on the glass, however, but the amount depends on the local condi ons and the adjustment of the air vent. Most of the soot layer will normally be burned off...
  • Page 44: Operational Problems Troubleshooting

    JØTUL F 620 Cast Iron side Right BP 51063410 JØTUL F 620 Convec on kit side FR/FL (same no. both sides) 50063453 JØTUL F 620 Convec on kit rear 50063035 Cover outside air F 620 B 50063921 Ash Lip F 620 51063919...
  • Page 45: Warranty Terms

    WARRANTY TERMS OUR WARRANTY COVERS: Jøtul AS guarantees that the external cast iron parts are free from material defects or produc on faults at the me of purchase. The warranty is valid for 5 years from the date of delivery. You can extend the warranty for external cast-iron parts to 25 years from the date of delivery by registering the product on jotul.com, and by prin ng the extended warranty card, within three months of the purchase.
  • Page 46 Jøtul con nuously strives to improve its products and reserves the right to modify specifi ca ons, colours and fi ngs without prior no ce. Quality Our quality policy should provide our customers with the security and quality experience that Jøtul has stood for ever since the business was founded in 1853. Jøtul AS, P.O.

This manual is also suitable for:

F 620 pF 620 lbF 620 b ht

Table of Contents