Jøtul F 45 V2 Greenville Installation and Operating Instructions The Jøtul F 45 V2 Greenville heater is listed to burn solid wood only. Do not burn any other fuels. Read this entire manual before you install and use this appliance. ...
139967 F 45 V2 3/20 Standards WARNING ! The Jøtul F 45 V2 Greenville non-catalytic heater has THIS WOOD HEATER HAS A MANUFACTURER- been tested and listed to: SET MINIMUM LOW BURN RATE THAT MUST U.S: ANSI/UL 1482-2011 NOT BE ALTERED. IT IS AGAINST FEDERAL Canada: CAN/ULC-S627-00 and ULC-S628-93 REGULATIONS TO ALTER THIS SETTING Certified Safety Tests performed by:...
139967 F 45 V2 3/20 Safety Notices • BURN SOLID, NATURAL WOOD FUEL ONLY. DO NOT BURN ANY OTHER FUEL. Recommended Tools • DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE. • Measuring Tap • Work Gloves DO NOT BURN GARBAGE OR FLAMABLE FUELS. •...
139967 F 45 V2 3/20 1.0 Installation 1.1 Unpack the Stove If this solid fuel room heater is not properly installed, a house fire may result. For your safety, follow the installation Inspect the stove for damage. Contact your dealer immediately if any damage is found.
139967 F 45 V2 3/20 1.5 Flue Collar Orientation The Flue Collar is oriented in the Top Exit position. To change orientation to Rear Exit: 1. Remove the Rear Shroud from the stove with removal of the four sheet metal screws at the top and bottom of the shroud sides.
139967 F 45 V2 3/20 2.0 Chimney Requirements 2.1 Masonry Chimneys There are two types of approved chimneys: 1. A code-approved masonry chimney with a ceramic tile Follow these guidelines when installing the Jøtul F 45 V2 or listed steel flue liner. into a masonry chimney: 2.
139967 F 45 V2 3/20 2.3 Chimney Height The chimney must be at least 3 feet higher than the highest point where it passes through the roof and at least 2 feet higher than the highest part of the roof or structure that is within 10 feet of the chimney, measured horizontally.
139967 F 45 V2 3/20 3.2 Hearthmount into a Masonry In Canada Fireplace The installation must conform to CAN/CSA-B365, Installation Code for Solid Fuel Burning Appliances and The Jøtul F 45 V2 on standard legs may be installed into a Equipment.
139967 F 45 V2 3/20 3.4 Mobile Home Installation The cross-sectional area of the flue of a chimney with one or more walls exposed to the outside below the roofline The Jøtul F 45 V2 is approved for installation in may be no more than two times the cross-sectional area of manufactured mobile homes provided the following the stove flue collar.
139967 F 45 V2 3/20 4.0 Clearance to Combustibles 2” 2” 4.1 Floor Protection The Bottom Heat Shield must remain on the stove unless the stove is installed on concrete poured on earth. The Jøtul F 45 V2 also requires one of the following forms of hearth protection if not installed directly on concrete poured 44”...
139967 F 45 V2 3/20 4.4 Using Shields to Reduce Clearances Double Wall Connector: Listed double wall pipe is an 17” acceptable alternative to connector pipe heat shields. Wall-Mounted Protection: When reducing clearances through the use of wall-mounted protection: Maximum 48”...
139967 F 45 V2 3/20 4.7 Jøtul F 45 V2 Greenville Clearance Specifications PROTECTED WALLS UNPROTECTED WALLS PER NFPA211 OR CAN/CSA- B365-M93 CORNER TO FRONT FLOOR CORNER TO FRONT FLOOR SIDE REAR CORNER FRONT FLOOR PROTECTION SIDE REAR CORNER FRONT FLOOR PROTECTION PROTECTION** WIDTH**...
139967 F 45 V2 3/20 5.0 Operation We recommend using a moisture meter to determine the moisture content of your wood. For purposes of home heating, your fuel should have a moisture content between Please read the following section before building the first 12 - 20%.
139967 F 45 V2 3/20 5.4 How Your Jøtul F 45 V2 Works FLOW DIAGRAM EXHAUST When used with dry wood and a well-drafting chimney PRIMARY system, modern non-catalytic wood stoves burn fuel SECONDARY efficiently by the precise control and delivery of primary and secondary air to the fire.
139967 F 45 V2 3/20 5.7 Break-In Procedure 5.8 Starting and Maintaining a Fire Although your Jøtul F 45 V2 is constructed of welded, 3/16” Burn only solid wood directly on the bottom of the steel plate, it also incorporates cast iron components. This stove firechamber.
139967 F 45 V2 3/20 5.10 Creosote Formation and the Need for Removal When wood is burned slowly, it produces tar and other vapors that combine with moisture to form creosote. Creosote vapors condense in the relatively cool chimney flue, and creosote residue accumulates on the flue lining. When ignited, this creosote fuels an extremely hot fire.
139967 F 45 V2 3/20 6.0 Maintenance 6.1 Door Latch Adjustment 6.2 Glass Care Over time, as the door gasket becomes compressed, it may Cleaning be necessary to adjust the door latch in order to maintain On occasion it will be necessary to clean the carbon deposits the integrity of the door seal.
139967 F 45 V2 3/20 6.6 Chimney System The Jøtul F 45 V2 is designed to burn cleanly and efficiently when used according to the guidelines in this manual. In order to maintain proper performance, you should inspect the chimney and chimney connector at the beginning of each heating season and then every other month during the heating season.
139967 F 45 V2 3/20 7.0 Appendix 2. Attach the Air Deflector to Rear Shroud: See figs. 21 and 23 /#3. Use pliers to bend the deflector tabs at the perforation lines as shown. Attach the deflector to the interior side of the rear shroud using two #8 X 12 sheet metal screws from the exterior side.
Page 22
139967 F 45 V2 3/20 Figure 21. Blower Parts Identification. Figure 23. Blower Parts Identification Rear Shroud Capture the bracket between the leg nut and the Lower Air Deflector bracket nut. Snapstat Blower Assembly Snapstat Bracket Blower Mounting Bracket Air Deflector M6 Flange Hex Nut (3) M6 Wingnut (2) Control Box Assembly...
139967 F 45 V2 3/20 7.2 Outside Air Kit 157637 Contents: • Outside Air Manifold Tools Required: • 10 mm and 1/4 “ socket drivers Remove four nuts and use • safety glasses to attach the manifold. • work gloves You will need to acquire the following additional components available at any hardware supplier •...
139967 F 45 V2 3/20 7.5 Alternate Floor Protection 7.4 Mobile Home Floor Bracket Kit 157321 All floor protection materials must be non-combustible ie. Metal, Contents: Floor Brackets , (2) brick, stone, mineral fiber boards). Any combustible material may Fastener Required: 3/8” dia. lag screw not be used.
139967 F 45 V2 3/20 7.6 Secondary Air Manifold 13. Resecure the secondary air manifold with turbulator to the stove. Use the 10mm open-end or socket wrench to install the Maintenance (2) M6x16 bolts into rear of stove. Tools Required: 14.
Page 26
139967 F 45 V2 3/20 (4) Sheet metal screws Figure 33. Verify manifold is seated properly Figure 30. Remove (4) screws from rear shroud (2) M6x16 Bolts Figure 31. Remove (2) M6x16 bolts from rear (2) M6x20 Bolts Figure 32. Remove (2) M6x20 bolts for smoke outlet...
139967 F 45 V2 3/20 7.7 F 45 V2 Start-Up and Refueling Follow these directions to get the best emissions performance from your F 45 V2: Low Fire Cold Start 1. At the end of the previous burn cycle, rake and arrange the remaining coals until they are equally distributed Use the following technique for the best start from and level across the firebox.
139967 F 45 V2 3/20 8.0 Jøtul F 45 V2 Greenville Illustrated Part Only use replacement parts provided through your authorized Jøtul dealer. Figure 35. F 45 V2 Greenville Illustrated Parts...
Page 29
139967 F 45 V2 3/20 8.1 Jøtul F 45 V2 Greenville Part List Description Part Number Description Part Number Screw, Button Head Socket - M6 x 10 Blk 117978 Blanket, Ceramic Fiber 226599 Glass Clip, 5” (three) 225008 Leg, Steel Stoves, Matte Black 157346 Gasket, Flat, V125x8mm (1/8”x5/16”), Self Adhesive 127215...
Page 30
139967 F 45 V2 3/20 This page is intentionally blank.
139967 F 45 V2 3/20 Over-firing occurs when any part of the stove glows red. Over-firing 9.0 F 45 V2 Warranty Statement can also be identified by warped plates, rust-colored cast iron, paint pigment that has turned dusty white, or bubbling, cracking and discol- Effective January 1, 2013 oration of the enamel finish.
Page 32
139967 F 45 V2 3/20 Quality We appreciate your trust in welcoming our product into your home and invite your comment and appraisal of our efforts to provide you with the finest in home hearth products. Jøtul pursues a policy of continuous product development. Products supplied may therefore differ in specification, colour and type of accessories from those illustrated and described in this manual.