Page 1
Jøtul F 600 Firelight CB Woodstove ........
Page 2
TABLE OF CONTENTS: Standards and Safety Notices Installations Chimney Requirements Connecting to the Chimney Clearances Alcove Installations Mobile Home Installations Operation Maintenance Accessories Parts Diagram Appendix A...
Page 3
NOTICES: · · · · · · Standards for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances · , Installation Code for Solid-Fuel-Burning Appliances and Equipment.
Page 5
Prefabricated Chimneys It is important that you check with your local building officials to find out what codes apply in your area before installing your new Firelight Remember: your local inspector(s) have the final authority in approving your installation. It is always best to consult with them prior to the installation.
Page 6
See figure 2. FIGURE 2 See figure 3. Installation Code for Solid Fuel Burning Appliances and Equipment Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances...
Page 7
FIGURE 3 FIGURE 4 See figure 5. See figure 4.
Page 8
FIGURE 7 FIGURE 5 See figure 6 and 7. See figure 8. FIGURE 6...
Page 9
HEARTH PROTECTION 50 8 200mm 18 8 460mm 200mm 55 FIGURE 8 18 460mm Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances Installation Code for Solid-Fuel Burning Appliances and Equipment WHEN CONSTRUCTING A NEW HEARTH OR FLOOR PAD, CONSULT APPENDIX A AT THE BACK OF THIS MANUAL FOR ALTERNATE MATERIALS AND METHODS.
Page 10
See figures 9 and 10. WARNING: DO NOT INSTALL IN A BEDROOM/SLEEPING ROOM. THE STRUCTURAL INTEGRITY OF THE MOBILE HOMES FLOOR, WALL, CEILING/ROOF MUST BE MAINTAINED. UNPROTECTED ALCOVE PROTECTED ALCOVE INSTALLATION* INSTALLATION* USE OF THE RIGHT SIDE LOAD DOOR IS PROHIBITED USE OF THE RIGHT SIDE LOAD DOOR IS PROHIBITED IN ALCOVE INSTALLATIONS.
Page 11
FIRELIGHT CB WOODSTOVE CLEARANCES UNPROTECTED SURFACE PROTECTED WALL ( PER NFPA 211) PARALLEL TO THE WALL PARALLEL TO THE WALL IMPORTANT: CONNECTOR HEATSHIELDS AND DOUBLE WALL PIPE MUST BE A LISTED PRODUCT. ALWAYS FOLLOW THE MANUFACTURES INSTRUCTIONS. UNPROTECTED SURFACE PROTECTED SURFACE (PER NFPA 211) CORNER INSTALLATION CORNER INSTALLATION...
Page 12
FIRELIGHT CB WOODSTOVE CLEARANCES UNPROTECTED SURFACE PROTECTED SURFACE NFPA 211 STOVE CLEARANCES PARALLEL INSTALLATION PARALLEL INSTALLATION SIDE REAR CORNER* SIDE REAR CORNER* Stove- no heatshields 13" 19" 13" 6" 12" 9" Single wall pipe 330mm 480mm 330mm 150mm 300mm 230mm Stove with rear heatshield 13"...
Page 13
° ° ° EVER BUILD OR ALLOW THE FIRE TO REST DIRECTLY ON THE GLASS HE LOGS SHOULD ALWAYS BE SPACED AT LEAST ONE INCH FROM THE GLASS TO ALLOW FOR ° PROPER AIR FLOW WITHIN THE STOVE URN ONLY SOLID WOOD DIRECTLY ON THE BOTTOM GRATE OF See figure 11.
Page 15
IMPORTANT: REPLACE GLASS ONLY WITH A CERAMIC GLASS PANEL SPECIFICALLY DESIGNED FOR THE JØTUL FIRELIGHT CB. DO NOT USE SUBSTITUTES. RE- PLACEMENT GLASS PANELS CAN BE ORDERED THROUGH YOUR JØTUL DEALER. FIGURE 13 See figure 13.
Outside Air Kit · · · WARNING: OPERATE YOUR JØTUL FIRELIGHT WITH T H E F R O N T D O O R S F U L LY O P E N A N D T H E FIRESCREEN IN PLACE OR FULLY CLOSED. PARTIALLY OPENED DOORS MAY RESULT IN OVERFIRING.
Page 17
PARTS LIST FOR THE FIRELIGHT CB ash door front ash lip right front door left front door right glass panel left glass panel front panel inner front panel side ash lip right side door right side door burn plate right side panel bottom right tube holder upper right tube holder tubes - font tube...
Page 20
Stoves and fireplaces must be installed to conform to local and national building regulations. Before preparing for the installation of the appliance, it is important that the instructions issued with the unit are carefully read and strictly adhered to. Jøtul pursue a policy of constant product development.