Maintenance of the SmartFork
Maintenance activities > Replacing components
EN
Removing the
weighing elec-
tronics
Installing the
weighing elec-
tronics
6.2.7.3
Replacing load cells
44
®
Scale
Fig. 17: Replacing the weighing electronics
2.
Remove the fork shoe from the SmartFork
on page 41).
3.
Unscrew and remove the two screws from the cover (Fig. 17/1).
4.
Remove the cover (Fig. 17/1) and put it to one side.
5.
Disconnect the cable connections (Fig. 17/3) on both sides of the weighing elec-
tronics by unplugging them.
6.
Remove the weighing electronics (Fig. 17/2).
1.
Establish the cable connections on both sides of the weighing electronics
(Fig. 17/3).
2.
Insert the weighing electronics (Fig. 17/2) into the recess.
3.
Put the cover (Fig. 17/1) on the recess and fasten it.
4.
Install the fork shoe of the SmartFork
on page 43.