Specifications; Unit Specifications - Sanyo SAP-K71GJA Technical & Service Manual

Split system air conditioner
Table of Contents

Advertisement

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – K71GJA
Outdoor Unit
SAP – C71GA
Power Source
Voltage rating
Capacity
Air circulation (High)
Moisture removal (High)
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB / 19°C WB
Outdoor air temperature 35°C DB / 24°C WB
V
kW
BTU/h
3
m
/h
Liters/h
V
A
W
%
W/W
A
Indoor / Outdoor
Horizontal
Vertical
g
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
m
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
kg
Net
Shipping
kg
m
220 – 240 V Single phase 50 Hz
220 / 230 / 240
2.05 / 2.05 / 2.05
7,000 / 7,000 / 7,000
3.0 / 3.0 / 3.0
640 / 660 / 680
3.20 / 3.11 / 3.01
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
3 and Auto / 1 (Hi)
Washable, Anti-Mold
Rotary (Hermetic)
Capillary tube
Optional / Hanging wall bracket
Indoor Unit
250
790
174
242
850
312
7.0
10.0
3
0.06
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
: http://splitoff.ru/tehn-doc.html
Cooling
370
0.55
198 to 264
97 / 96 / 94
16 / 17 / 17
Manual
Auto
R22 / 670
36 / 33 / 31
45
Flare type
7.5
6.35 (1/4)
9.52 (3/8)
Outdoor Unit
530
680
225
580
812
315
25.0
27.0
0.15