Specifications; Unit Specifications - Sanyo SAP-K71GJA-S Technical & Service Manual

Table of Contents

Advertisement

2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – K71GJA
Outdoor Unit
SAP – C71GA
Power Source
Voltage rating
Capacity
Air circulation (High)
Moisture removal (High)
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB / 19°C WB
Outdoor air temperature 35°C DB / 24°C WB
BTU/h
m
Liters/h
W/W
Indoor / Outdoor
Horizontal
Vertical
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
220 – 240 V Single phase 50 Hz
V
kW
3
/h
V
A
W
%
A
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
g
m
Optional / Hanging wall bracket
Indoor Unit
mm
250
mm
790
mm
174
mm
242
mm
850
mm
312
kg
7.0
kg
10.0
3
m
0.06
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
220 / 230 / 240
Cooling
2.05 / 2.05 / 2.05
7,000 / 7,000 / 7,000
370
0.55
198 to 264
3.0 / 3.0 / 3.0
640 / 660 / 680
97 / 96 / 94
3.20 / 3.11 / 3.01
16 / 17 / 17
3 and Auto / 1 (Hi)
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R22 / 670
Capillary tube
36 / 33 / 31
45
Flare type
7.5
6.35 (1/4)
9.52 (3/8)
Outdoor Unit
530
680
225
580
812
315
25.0
27.0
0.15