2-3. Other Component Specifications

Indoor Unit
SAP – K71GJA
SAP – K91GJA
SAP – K121GJA
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Thermistor (Coil sensor)
Resistance
Thermistor (Room sensor)
Resistance
Outdoor Unit
SAP – C71GA
SAP – C91GA
SAP – C121GA
Power Relay (PR)
Coil rating
Coil resistance
Contact rating
Thermostat (Fan Speed Control 23S)
Switching temp.
Contact rating
Primary
Secondary
Capacity
Ω (at 21°C)
kΩ
kΩ
SAP – C91JA
SAP – C121JA
Ω (at 23°C)
°C
ATR-J105
AC 230V, 50 / 60 Hz
19V, 0.526A
Primary (WHT – WHT):
Secondary (BRN – BRN):
DTN-TKS131B
0°C
DTN-TKS128B
25°C
G7L-2A-TUB
AC 200 – 240V, 50/60Hz
21 ± 15%
AC 220V, 25A
high
LOW
low
HIGH
AC 220V, 3A
15
: http://splitoff.ru/tehn-doc.html
10VA
205 ± 10%
2.0 ± 10%
150°C
15.0 ± 2%
5.0 ± 3%
MQT5S
28.5°C ± 1.5
31.5°C ± 2
<Only for SAP-C121 models>