2. SPECIFICATIONS

2-1. Unit Specifications

Indoor Unit
SAP – K301AH
Outdoor Unit
SAP – C301AH
Power Source
Voltage rating
Capacity
Air circulation (High)
Moisture removal (High)
Available voltage range
Running amperes
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
Controls / Temperature control
Control unit
Timer
Fan speeds
Airflow direction (Indoor)
Air filter
Compressor
Refrigerant / Amount charged at shipment
Refrigerant control
Operation sound
Refrigerant tubing connections
Max. allowable tubing length at shipment
Refrigerant tube
diameter
Refrigerant tube kit / Accessories
Unit dimensions
Package dimensions
Weight
Shipping volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
BTU/h
m
Liters/h
W/W
Indoor / Outdoor
Horizontal
Vertical
Indoor – Hi / Me / Lo
dB-A
Outdoor – Hi
dB-A
Narrow tube
mm (in.)
Wide tube
mm (in.)
Height
Width
Depth
Height
Width
Depth
Net
Shipping
240 V Single phase 50Hz
V
Cooling
kW
8.00
27,300
3
/h
1,110
3.4
V
A
13.0
W
3,100
%
99
2.58
A
Microprocessor / I.C. thermostat
Wireless remote control unit
1-hour OFF / 12-hour ON or OFF
3 and Auto / Auto (Hi, Lo)
g
47 / 42 / 38
54
m
Optional / Hanging wall bracket
Indoor Unit
mm
330
mm
1,140
mm
228
mm
325
mm
1,231
mm
406
kg
18.0
kg
20.0
3
m
0.16
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2
240
Heating
9.00
30,700
1,170
216 to 264
12.0
2,850
3.16
63
Manual
Auto
Washable, Anti-Mold
Rotary (Hermetic)
R22 / 2,800
Capillary tube
47 / 41 / 38
Flare type
7.5
9.52 (3/8)
15.88 (5/8)
Outdoor Unit
735
940
340
826
1,016
416
71.0
77.0
0.35
99
54