OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED UNDERCOUNTER CABINETS

ELECTRICAL SPECIFICATIONS:

MODEL
H-339-X-128C,
UA-8C, 188C,
12-188C, 1813C
H-339-X-128C-240,
188C-240, 12-188C-240,
1813C-240, UA-8C-240

HOW TO INSTALL UNIT:

1. Plug cord into 15-amp wall outlet.
2. Place cabinet in a well ventilated area.
3. Insert pan slides into the cabinet.
4. Push the switch on, turn the thermostat to No. 10
and run the unit for one hour.
NOTE: DO NOT PUT IN FOOD!
This step is to burn off manufacturing oils and
excessive adhesive.
5. Let the cabinet cool and wipe inside clean with
detergent and hot water before use.
HOW TO OPERATE UNIT: (Figure 1)
1. Push switch "ON". Yellow light will come on.
2. Turn thermostat to the temperature you need.
NOTE: No. 7½ setting will give you about 180° F.
Proper food holding temperature is 140° F or
higher.
3. Preheat cabinet for 45 minutes
4. Put food into cabinet.
5. Turn the wing nut on the door vent to open the
vent when less humidity is needed.
To Turn Off Unit:
Push switch "OFF". The yellow light will go off.
NOTE: Thermometer gives the inside cabinet
temperature.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MODEL H-339-X-C Series
Volts
Watts
120
900
240
900
Insulated
Holding Cabinet
Rev. 4 (5/14)
Amps
Hertz
Phase
7.5
60
3.8
60
Figure 1
Control Panel
FL-2300
Page 1 of 4
NEMA
1
5-15
1
6-15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H-339-X-C Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Cres Cor H-339-X-C Series

  • Page 1 To Turn Off Unit: Figure 1 Push switch “OFF”. The yellow light will go off. Control Panel NOTE: Thermometer gives the inside cabinet temperature. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 2 Move latch forward or backward to adjust b. Move strike up or down for alignment to magnetic draw. magnet on latch. c. Tighten screws to secure. c. Tighten screws to secure Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 3 Instructions for replacing parts are included in replacement parts kits. KIT NUMBERS FOR H-339 MODELS DESCRIPTION -UA-8C -128C -188C 12-188C -1813C Door Kit 5508-085-K 5508-083-K 5508-084-K 5508-084-K 5508-084-K Rack Insert 0621-281-K 1170-129 1170-130 1170-122 1137-130-03 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 4 Insulated FL-2300 Holding Cabinet Rev. 4 (5/14) Page 4 of 4 5925 Heisley Road • Mentor, OH 44060-1833 MAINTENANCE INSTRUCTIONS > Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...

This manual is also suitable for:

H-339-x-128cH-339-x-ua-8cH-339-x-188cH-339-x-12-188cH-339-x-1813cH-339-x-128c-240 ... Show all

Table of Contents