functions of Lock_Bit123 can be found. They are as follows:
 MOVC instructions executed.
 Verify is disabled.
 External execution is disabled.
 Executing one function will finish several operations. The user should select the
function according to the manual in order to avoid misoperations.
 Lock_Bit 1&2&3 OK!: Successful protection.
 0:00'09''23 elapsed: Executing Auto takes 9.23 seconds.
 Programmer not found: the red words mean that errors have occurred. Read the
error information.
4.8 Status Bar
This bar displays the menu item information, the progress of operation, and a Cancel
button.
If the 'Cancel' button is clicked, the operation which is being performed will be
stopped and the following dialog box will pop up:
 Cancel process. Continue?
Before the user confirms the 'Cancel' operation, the operation continues. The
'Cancel' operation may destroy the chip, please use it carefully.
4.9 Statistic Window
 Statistical Information
The times of successful and failed programming are recorded. The default counting
rules:
1. When "Program" is executed, if it succeeds the success count increases by 1,
otherwise the failure count increases by 1.
2. When "Auto" is executed, if the "Auto" contains "Program" and the "Program"
succeeds the success count increases by 1, otherwise the failure count increases by 1.
Except for the operations, all the operations are not related to the special status bar.
Refer to "Operation Option".