A
Switch
Three position switch (1 0 R).
0 Heat pump off.
1 Normal mode.
All control functions connected.
R Standby. Not connected at the factory
Function keys
B
Channel
Window menu selection.
Increase
Increases the current value.
Reduce
Reduces the current value.
Operating mode
Additional heat (accessory) and/or room
heat on/off. See the following section.
Extra hot water
Temporary or periodic raising of the
water temperature is allowed (accesso-
ry).
C
Display
In normal mode the display shows:
WW-out: Actual heating water temperature, the
temperature of the water leaving the heat pump.
The figure in brackets shows the calculated flow
temperature.
Hot water: Actual hot water temperature
(accessory).
Setting different operating modes (also applies with accessories)
Normal mode (basic setting):
Supplement ready to start if needed. Hot water
charging cuts in if necessary.
LEDs:
Room heating:
Lit
Hot water:
Lit during hot water charging
Additional heat
Flashing / Steady light
No additional heat mode:
Press the Operating mode button once.
Room heating:
Lit
Hot water:
Lit during hot water charging
Additional heat
Not lit
Position No room heating:
Press the Operating mode button again.
Room heating:
Not lit
Hot water:
Lit during hot water charging
Additional heat
Not lit
Front panel

Functions

D
E
The system returns to normal mode the next time the
Operating mode button is pressed.
Temporarily raised hot water temperature:
Press the Extra hot water button once. A raised hot
water temperature is obtained for 24 hours. The Hot
water LED flashes rapidly. Lit during charging.
Periodically raised hot water temperature:
Press the Extra hot water button again. The hot water
temperature is raised as shown on menu 12. The Hot
water LED flashes slowly. Lit during hot water charging.
The next time Extra hot water is pressed you return to
normal mode.
* Only possible with an external immersion heater.
FIGHTER 1310
Indicator lamps
Room heating
– A steady light indicates that room
heating is allowed.
Heat pump
– A flashing light shows that a compres-
sor is running.
– A steady light shows that both com-
pressors are running.
Hot water (accessory)
– A steady light shows that hot water
charging is in progress.
– Rapid flashing shows that temporary
raising of the hot water temperature
has been selected (approx 60 °C for
24 hours)*.
– Slow flashing shows that periodic rais-
ing of the hot water temperature has
been selected (approx 60 °C for the
chosen period)*.
Additional heat (external)
– A steady light means that the addition-
al heating is on.
– Slow flashing means that additional
heating is allowed.
– Rapid flashing means that only addi-
tional heating is on.
Alarm
Flashes
rapidly
occurred.
Raise/lower heat
This knob is used to raise or lower the room
temperature (i.e. it changes the temperature of
the WW-out). Applies to docking options 1 and
3.
Normal mode: No raised hot water temperature
connected.