Switch
A
Three position switch (1 – 0 –
0 The heat pump completely switched off.
1 Normal mode. All control functions connect-
ed.
Standby mode, heat medium pump and elec-
trical element step 2 only.
Function keys
B
Channel
Window menu selection.
Increase
Increases the current value.
Reduce
Reduces the current value.
Operating mode
Additional heat and/or room heat on/off.
See the following section.
Extra hot water
Temporary or periodic increase in the hot
water temperature.
Display
C
In normal mode the display shows:
WW-out: Current heat medium temperature
(temperature of the water out of the heat pump).
Hot water: Current hot water temperature.
Normal mode (basic setting):
Supplement ready to start if needed. Hot water-
charging cuts in if necessary.
LEDs:
Room heating:
Lit
Hot water:
Lit during hot water charging
Additional heat
Flashing / Steady light
No additional heat mode:
Press the Operating mode button once.
LEDs:
Room heating:
Lit
Hot water:
Lit during hot water charging
Additional heat
Not lit
No room heating mode (only hot water):
Press the Operating mode button again.
LEDs:
Room heating:
Not lit
Hot water:
Lit during hot water charging
Additional heat
Not lit
The system returns to normal mode the next time the
Operating mode button is pressed.
Front panel

Functions

).

Setting different operating modes

FIGHTER 1210
Indicator lamps
D
Room heating
Shows room heating is allowed when lit
(circulation pump in operation).
Heat pump
– Shows the compressor is running
when lit.
Hot water
– A steady light shows that hot water
charging is in progress.
– Flashes
increase of the hot water temperature
is selected (approx. 60°C during 24
hours).
– Flashes slowly when periodic increase
of the hot water temperature is select-
ed (approx. 60°C in accordance with
the selected interval).
Additional heat
– A steady light means that the addition-
al heating is on.
– Flashes slowly when additional heat is
allowed.
– Flashing rapidly when only additional
heat is on.
Alarm
Flashes
rapidly
occurred.
Raise/lower heat
E
The Increase/reduce heat knob raises or lowers
the room temperature (changes the tempera-
ture of WW-out).
Normal mode:
No increased HW temp connected.
Temporarily raised hot water temperature:
Press the Extra hot water button once. A raised hot
water temperature is obtained for 24 hours. The Hot
water LED flashes rapidly.
Lit during charging.
Periodically raised hot water temperature:
Press the Extra HW button once. The hot water
temperature is raised as shown on menu 12. The Hot
water LED flashes slowly. Lit during hot water
charging.
The next time Extra HW is pressed you return to nor-
mal mode.
For Home Owners
5
rapidly
when
temporary
when
a
fault
has