Nonin CO-Pilot™
Wireless Handheld Multi-
Parameter System (H500)
Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for Nonin CO-Pilot H500

  • Page 1 Nonin CO-Pilot™ Wireless Handheld Multi- Parameter System (H500) Quick Start Guide...
  • Page 2: System Components

    Refer to the CO-Pilot Wireless Handheld Multi-Parameter System (H500) Operator’s Manual for complete instructions for use to fully understand the device, its operation, and the potential risks to user and patient. Table of Contents System Components Display Icons and Indicators Initial System Set Up Taking a Measurement Placing Disposable rSO...
  • Page 3: Display Icons & Indicators

    02 Display Icons & Indicators Multi-Sensing Display Screen Display Battery Indicator Pulse Signal Quality Indicator Pulse Wave Form/ Display Screen Display Charging Port Histograms On/Off, Trending readings of the Sleep Button value over time Signal Processor Session ID Serial Number Signal Processor Event Marker Button Battery Life...
  • Page 4: Initial System Setup

    03 Initial System Setup Charge display and signal processor per instructions in Section 9 Press and hold On/Off button on signal processor until green LEDs blink on and blue Bluetooth LED begins to blink Press and hold On/Off,Sleep button on display until screen turns on Connect sensor to signal processor and engage sensor lock (Figure 1)
  • Page 5 05 Placing Disposable rSO Sensor Connect INT-100 to signal processor as shown in Figure 1 Connect 8204CA sensor to INT-100 and engage Figure 3 lock per Figure 3 Remove the protective backing from the sensor pad and gently, but firmly place the sensor above the eyebrow per Figure 4 Ensure sensor surface adheres to the skin to prevent light from traveling between emitting...
  • Page 6: Charging The System

    Critical (0-4%), charge SP-BLE No Lights Depleted or off 09 Charging the System Charge the display and signal processor (SP- BLE) using the provided Nonin chargers ONLY* Insert charger into respective ports shown below to charge. SP-BLE Charging Port Display...
  • Page 7: Basic Troubleshooting

    10 Long Term Storage Mode To place the display into long term storage mode, press and hold the On/Off, Sleep button on the display (Figure 2) until screen prompt appears Choose “Power Off” on display screen. Screen will go black, display is now in long term storage mode To place the signal processor into long term storage mode,...
  • Page 8 12 COHb Quick Reference Carbon monoxide (CO) is an odorless, colorless gas that can remain undetectable until exposure results in injury or death. CO poisoning can lead to a variety of clinical effects that resemble many neurological and cardiovascular conditions, leading to potential misdiagnosis.
  • Page 9 Treatment Carbon Monoxide: Half Life Elimination from Blood Room Air 240-360 minutes Oxygen (100%) 80 minutes Hyperbaric Oxygen (HBO) 22 minutes 13 COHB Exposure Treatment Decision Process If CO exposure is NOT suspected: Noninvasive COHb values should NOT be used If CO exposure IS suspected: Patient has signs and symptoms, transportation to the hospital is recommended even if the COHb...
  • Page 10 Nonin Medical B.V. Doctor Paul Janssenweg 150 5026 RH Tilburg • Netherlands Tel: +31 (0)13-79 99 040 Fax: +1 (0)13-79 99 042 Email: infointl@nonin.com © 2020 Nonin Medical, Inc. All trademarks are the property of Nonin Medical, unless otherwise noted.