Specifications (continued)
Output Signals/Channels
Pulse-pause outputs
System ready
End of pulse sequence
Temp. dispensing fluid
Dispensing sequence fault
Analog output
Output load

Standards

• The PICO controller is intended to be operated with 24 VDC and complies with EMC guideline 2014/30/EU-EMV/
EMC/CEM.
• The unit has the CE mark of conformity.
• The unit was inspected pursuant to the environmental testing method IEC 68.
www.nordsonefd.com info@nordsonefd.com
Electrical 24 V impulses to control dispensing sequences
0 V = not ready, 24 V = ready
24 V pulse, duration 100 ms
24 V = fluid temperature okay, 0 V = fluid temperature not reached or exceeded
24 V = normal, 0 V = dispensing sequence fault (container limit reached upon level check or
faulty/missing PICO Toµch controller)
Temperature (0–5 V for 0–100 ºC or 0–10 V for 0–200 ºC can be configured) setpoint for the fluid
Per pulse output: max. 2 W (80 mA)
Per analog output: max. 10 mA
Per other output: max. 0.5 W (20 mA)