• Fixed Installation
Insert the fi xed installation cables (L-N-
control box. Fasten the cables, passing them through the fi xture clamp. Connect the ca-
bles to the terminal strip: (L) brown color, (N) Blue color,
• By means of fl exible cable and plug (not supplied)
These must have the following technical specifi cations:
Type of fl exible cable: H05VV-F 3G x 0.75 mm
Plug: 250V AC 16A with 2P + ground connection.
Insert the fl exible cable through the access hole to the inside of the control box. Secure
the fl exible cable, fastening it with the fi xture clamp. Connect the fl exible's wires to the
terminal strip: (L) brown color, (N) Blue color,
Break the groove on the rear part of the base to be able to feed the fl exible cable through
it and connect it to the corresponding power socket.
• Using the device as a template, mark the position of the four holes on the wall.
Make the 4 holes (diameter 5 mm), insert the rawlplugs and fi x the device with the four
screws provided.
• Put the front cover back on, making sure that it has been fi xed properly by the two side tabs.

4. OPERATION

1. Pulling the rotary switch cord turns the device on. On the front lens you can see the fo-
llowing symbols. You can change the operating power by pulling successively on the cord,
until you turn it off.
Model
INFRARED-125
INFRARED-125
2. INFRARED-155 model (Figure 8)
The INFRARED-155 model incorporates a movement sensor to increase the energy saving
without diminishing the user's comfort. This system is very useful for public washrooms,
changing rooms, gyms and other spaces with constant movement of persons. This sensor
automatically controls the activation / deactivation of the device, preventing the heater
staying on with no users present.
− By pulling successively on the cord, you can turn the device off/on and select the desi-
red operating power.
− At the instant the sensor doesn't detect any movement inside the room/bathroom, it
will start counting. If the sensor doesn't detect any movement after 5 minutes the hea-
ter will stop automatically and go into standby mode.
− At the instant movement is detected again within the sensor's area of infl uence (Figu-
re 8), the heater will turn on again at the pre-selected power.
This model also incorporates an adjustable run-on timer. Independently of the presence
sensor, the device will stop after the run-on time set and the user will have to turn the
heater on again by pulling the cord. You have the option to deactivate this timer. See the
following section.
14
) through the access hole to the inside of the
0
OFF
600 W
OFF
750 W
(Yellow-green).
2
/ Length less than 2 m.
(Yellow-green).
1.200 W
1.500 W