Identification
1. Jaw
2. Lever
3. Display
4. Common (COM) input terminal
5. Volts or resistance (V-Ω) input terminal
6. ON/OFF/HOLD button

Display Icons

7.
Low battery indicator
8. –
Polarity indicator
9.
Measured voltage is greater than
30 volts AC or DC
10.
Automatic selection is active
AutoSense
11.
Automatic Power Off is enabled
12.
Hold function is enabled
AutoHold
13.
Low input impedance is active
LoZi
14. AC
AC measurement is selected
15.
Continuity
16. DC
DC measurement is selected
17.
Diode
18. A
Amperes
19. V
Voltage
20. %
Percent
21. k
Kilo (10
22. Ω
Ohms
23. OL
Overload indicator
Note: Icons that
appear on the display
but are not identified
are not used on this
model.
Symbols on the Unit
Warning—Read the instruction manual
Electric shock hazard
Application around and removal from hazardous live conductors is permitted.
Double insulation
Battery
Recycle product in accordance with manufacturer's directions
6
)
3
10-11
9
8
7
1
2
3
4
23
2
6
5
12-14
15-16
17-19
20-22