Section 5 - Setup
Beacon/Alarm Setup
The Beacon/Alarm Setup allows a specific Beacon, designated by number, to be set to indicate one of several
conditions:
Ready & Level
Pump On
Power On
Ready
Alarm Level
The alarm may also be set to "Disabled," which is the factory default setting.
J30, on the New CPU, provides a +24VDC - GND connection for each beacon/alarm desired. This output is +24VDC,
0.5A.
The beacon assembly is available as an option: a two-light version and a two-light-with-alarm version. The two lights
are blue and red. The beacon will be enabled if this option is ordered from the factory. The condition for the red light
(beacon #2) and the alarm are tied together. The factory settings are shown below.
This parameter can be accessed in Password Level 2 or higher (see Appendix A - Password Levels).
Level 1
Level2
Setback On
Fault/Stop
Pressure Alarm
Light Color
Blue
Red
Alarm
Condition
System Ready
Fault
Fault
56
MM113 - D10/D16 Hot Melt Unit