D4-E Hot Melt Unit Manual Number: MM101 Release Date: 9/2009 Software Revision: C018...
Page 2
Directives by the person responsible for the final assembly. Orcoyen, on :_____________ Signed.:______________________ Gonzalo Marco, Managing Director VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com ORCOYEN, NAVARRA (SPAIN)
Page 3
CONTROL REGISTRATION CONTROL : ..............DATE: ................ELECTRIC CHECK: CONTROL BOARD CHECK: TEMPERATURE CONTROL CHECK 150/180°C: HYDRAULIC CHECK (100 bar): PNEUMATIC CHECK: APPLICATOR SERIAL NUMBER: GUARANTEE CARD DISTRIBUTOR:..........................CONTACT:............................OEM:..............................ADDRESS:............................USER:..............................CONTACT:............................ADDRESS:..................TELEPHONE :.......
Over Temperature Alarm Under Temperature Alarm Maximum Temperature Automatic Pump Mode Setback Temperature MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 5
Manifold Assembly Motor Assembly Front Panel Assembly Central Cover Assembly Rear Panel Assembly MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 6
Setup Button Sub Menu - History* Setup Button Sub Menu - Diagnostics* MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
SECTION 1 – INTRODUCTION ValcoMelton, a division of Valco Cincinnati, Inc., has prepared this manual as an aid for installing, operating, and servicing the D4-E hot melt unit. It also contains a list of part numbers for replacement parts. If you need more information, contact your ValcoMelton representative.
OTHERWISE, DEATH OR OCCUR. Only qualified personnel should open and service. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 9
OTHERWISE DEATH, PERSONAL INJURY, OR EQUIPMENT DAMAGE COULD OCCUR. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
SECTION 4 - INSTALLATION The D4-E hot melt unit is assembled at the factory. However, the power Choosing a and the glue hoses must be connected by the customer. This section Location contains instructions for making the necessary connections. While choosing a location for the unit, keep in mind that: •...
Otherwise, equipment may not function properly MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 16
Failure to observe could result in personal injury, death, or damage to equipment. The D4-E hot melt units are configured at the factory to use one of the following power sources: •...
Page 17
“E” Series 5 Zones Borrad 151xx616 (120V) Rev D MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 18
“E” Series 5 Zone Borrad 151xx606 (240V) Rev D MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
• Maintain separation between hoses to avoid hot spots. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 20
4. Select the end of the glue hose that has the lead assembly with the male electrical connector (Figure 5-1). MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 21
The use of two wrenches prevents the hose from twisting inside while it is being tightened. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
3. Connect the hot melt hose lead assembly’s female connector to the lead assembly on the applicator. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
This output is rates for +24V DC@250 mA Max. The unit can be connected to several PLC/sensor types. See the following examples diagrams for MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 31
23 Clock On/Off LED Illuminates green when the clock function is on MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Power On/Off Switch D4-E Unit The Standby Button controls the power to the D4-E Unit. Press the Standby Button once. The display screen will come on and the Standby LED will illuminate green, indicating that the unit is on. When the Standby Button is pressed again, the display screen will go blank and the Standby LED will illuminate orange, indicating the unit is in Standby Mode.
To enter a password: (Press the powr button to turn the unit on) MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
The Fault History and the Change History are cleared when the unit is turned off. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
See the next page for an in-depth review. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 59
This screen states that for Shift C, nothing will be on, since there is no Shift C working. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 60
Clock Function is On and is set properly MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
The D4-E unit contains a single-stage relief valve (see figure below). Adjusting the Additionally, the D4-E unit can use an optional pneumatic relief valve Pressure (707xx212). Control Valve The single-stage relief valve is a simple safety device which protects the system from excessive pressure.
Button and the OK Button on the keypad. The buttons can be released once the start-up screen appears. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Standby LED Green = unit on Orange = unit in Standby Mode MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 65
Gun 1/Gun 2 Zone LEDs Hose 1/Hose 2 Zone LEDs Reservoir (Tank) Zone LED MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Page 66
Ready LED must be illuminated green for the pump to operate. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Ready LED must be illuminated for the pump to operate. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
(Setback LED illuminated yellow) to put the unit into setback manually. To exit setback mode, press the Setback Button again (LED not illuminated) MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
To clean the exterior of the D4-E hot melt unit, follow these steps: Clearing the Exterior of Caution! Never hose- or steam-clean the unit. If the surrounding area the Unit is cleaned in this manner, protect the unit by covering it with plastic or other waterproof material.
Page 74
4. Disconnect glue hoses from applicators and collect purged material with appropriate container. 5. Turn the D4-E hot melt unit on and allow 20-30 minutes for hoses and guns to reach temperature. 6. Turn the pump on.
Thread a new filter assembly into the manifold. See Section 10 Part Number List for more information. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
No charge will be made for parts and labor. MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...
Any hose/gun pair 1400W Total for all hoses and all guns 2800W MM101 – D-4E HOT MELT UNIT VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA TEL: +34 948 321580 Fax: +34 948 326584 melton@melton.es www.valcomelton.com...