4 . TRIMMING TIME CHART

ON
Start sw.
OFF
ON
[DSW]
OFF
ON
[SRC]
OFF
ON
[T]
OFF
ON
[UP]
OFF
ON
[SRT]
OFF
ON
[FN4]
OFF
UP
Presser
foot
DOWN
OPEN
Tension
release
CLOSE
PULL
Thread
puller
BACK
GO
Wiper
sweep
BACK
ON
Heater
OFF
UP
Thickness
detector
DOWN
GO
Lower
trimmer
BACK
GO
Upper
trimmer
BACK
[DSW] : Sewing in progress output signal (by system)
[SRC] : Start prohibit unput signal (by step sequence)
[T] : Thread trimming output signal (output by teaching data)
[UP] : Up position output signal (by system)
[SRT] : Start input signal (output by teaching data)
[FN4] : Function No.4 output signal (output by teaching data)
Heater protection : In the trimming process, heater is automatically off after 2.5 sec in spite of trimming process is end
sew
Pre heating
or not. In any time, heater can be off by pressing the halt switch.
trim
400ms
350ms
1000ms
sew
(feed)