Diagnostics; Diagnostic Memory - Ultra Start 25XX Series Install Manual

Remote starter/ alarms
Table of Contents

Advertisement

INSTALLATION MANUAL
Page 24

DIAGNOSTICS

If the remote starter does not activate when the start button is pressed the park lights
will flash a diagnostic to indicate what shutdown input has been triggered. For example
when the start button is pressed the park lights flash 3 times slowly. Looking at the chart
below this would indicate that the system is in Service Mode, simply follow the
instructions listed in the owners manual on exiting Service Mode and the remote starter
will begin to function as normal.
PARK LIGHTS
3 Flashes
3 Slow Flashes
4 Slow Flashes
5 Flashes
5 Slow Flashes
6 Flashes
7 Flashes

DIAGNOSTIC MEMORY

LED Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
Being that the installer does not always see when the system shuts down or fails to
start, Diagnostic Memory will store in memory up to four shutdown codes.
This information can then be accessed to determine the source of the shutdown.
To Enter Diagnostic Mode:
Step 1 - Turn the ignition on then turn off. Press the Program Button and release.
Step 2 - The system will respond with three park light flashes and the siren will chirp
the same number of times as the events in memory.
Maximum four events, four chirps
NOTE: If the siren does not chirp, there are no events in memory.
Step 3 - Press the Program Button once to view the last shut down code. The siren
will chirp once to confirm code one.
If the horn does not chirp, there are no codes in memory.
Step 4 - The LEDs on the antenna will flash a code corresponding to a shut down trigger.
Press the Program Button again to check the second code.
The siren will chirp twice to confirm code two.
Step 5 - To Clear Diagnostic Memory. While in Diagnostic Mode press and hold the
Program Button for five seconds.
The park lights will flash and the siren will chirp once.
NOTE: Once diagnostic memory has 4 shutdown events in memory, the system will not
Record any further shutdown events until the system memory has been cleared.
STATUS LED
Series of 3 Flashes
LED's On Solid
Series of 4 Flashes
Series of 5 Flashes
Series of 5 Flashes
Series of 6 Flashes
Series of 7 Flashes
Diagnostic
The system was shutdown by the brake switch input
The system was shutdown by the hood pin input
The system did not detect the tach signal.
The system made 3 start attempts without starting
REMOTE VEHICLE STARTER/ALARM
DIAGNOSTIC CODE
Door Opened "M" Models
System Is In Service Mode
Not in Reservation Mode "M" units
Ignition On During Start Attempt
Brake Pedal Shutdown
Hood Pin Opened
Tach Lock-Out