Without Tilting Bracket; Using Side By Side Bracket; Figure 12. Rrh Arrangement_3 Sector Pole Type Installation - Samsung RT4401-48A Installation Manual

Table of Contents

Advertisement

The dimensions of the RRH change according to the tilt angle, and the maximum
dimensions are described in the figure above (RRH Arrangement_Down, Up
Tilting 15°).

Without Tilting Bracket

The figures below depict the recommended distances for each direction of the
RRH without using the tilting bracket.

Figure 12. RRH Arrangement_3 Sector Pole Type Installation

23.0 (584)
※ Example for 200 A pole
[Front View]

Using Side by Side Bracket

The figures below depict the recommended distances for each direction of the
RRH using the side by side bracket for the pole type installation.
RT4401-48A Installation Manual v3.0
Copyright © 2019, All Rights Reserved.
Pole
(Ф 8.7 in./220 mm)
≥ 32 (800)
Chapter 2 Installing System
Unit: in. (mm)
[Top View]
≥ 32 (800)
17