Bosch FSR Series Training Manual page 67

Table of Contents

Advertisement

Service (Electric or Gas Default) Cont'd
Function 2:
1.
Display CONV FAN (if applicable for version)
2.
Press Start to activate the convection fan relay.
3.
Display ON
4.
Press Start to de-activate the convection fan relay.
5.
Display CONV FAN
6.
Allow user to continue toggling.
7.
Rotating the selection knob will de-activate the fan relay (if on) and scroll display to function select.
Function 2A:
1.
Display COOLING FAN (SIR only)
2.
Press Start to activate the cooling fan relay.
3.
Display ON for 6 seconds, then control should monitor for feedback signal from fan
If signal is registered, display SIGNAL PRESENT
If no signal is registered, display ERROR NO SIGNAL
4.
Press Start to de-activate the cooling fan relay.
5.
Display COOLING FAN
6.
Allow user to continue toggling.
7.
Rotating the selection knob will de-activate the fan relay (if on) and scroll display to function select
(Light, Fan, Ring, etc.). Note: If Start is pressed before the 6 seconds are completed, the fan turns
off and the signal not checked.
Jan. 2008, Iss. 1