Avaya S8700 Maintenance Manual page 2445

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

UDS1-BD (UDS1 Interface Circuit Pack)
Table 8-667. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
2306
Any
Yellow Alarm Inquiry
test (#141)
2561
Any
Major Alarm Inquiry test
(#142)
2817
Minor Alarm Inquiry test
(#143)
3073 to
Any
Slip Alarm Inquiry test
3160 (v)
(#144)
3330(w)
46083
3585 to
Any
Misframe Alarm Inquiry
3601 (x)
test (#145)
3840(y)
Any
None
3841(z)
4358
3842(aa)
46097
3843(ab)
46081
3900(ac)
Any
CPE Loop-Back Jack
test (#1212)
3901(ad)
Any
Far CSU Loopback test
(#1213)
3902(ae)
Any
One-Way Span test
(#1214)
3999(af)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit pack,
then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period of 15
minutes. Warning alarms are also raised against any ports administered on the circuit pack.
3.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
4.
Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the set options
command.
555-233-143
Alarm
On/Off
Level
Board
3
WARNING
OFF
MINOR
3
WARNING
OFF
MINOR
3
WARNING
OFF
MINOR
3
WARNING
OFF
MINOR
3
WARNING
ON
MINOR
3
WARNING
OFF
MINOR
Issue 1 May 2002
Test to Clear Value
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS r 6
test board UUCSS r 6
Continued on next page
8-1723

Advertisement

Table of Contents
loading