Maintenance-Object Repair Procedures
Table 8-688. Test #1215 Inject Single Bit Error Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
A single bit error has been successfully injected into an active framed 3-in-24
test pattern.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Execute the add ds1
2. If the board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, then issue the
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
8-1802
Issue 1 May 2002
UUCSS command to administer the UDS1 interface if it is not already
administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
busyout board command.
Continued on next page