Removal And Replacement Of Float Switch; Removal And Replacement Of Spray Tube - Hoshizaki KM-150BAF Service Manual

Crescent cuber
Hide thumbs Also See for KM-150BAF:
Table of Contents

Advertisement

12) Close the Bin Door.
13) Replace the panels in their correct positions.
14) Plug in the icemaker, and turn on the power supply.

14. REMOVAL AND REPLACEMENT OF FLOAT SWITCH

1) Go through the steps 1) through 7) in "13. REMOVAL AND REPLACEMENT OF
PUMP MOTOR."
2) Remove the connectors of the Float Switch.
3) Remove the screw and the Float Switch Bracket.
4) Remove the two screws and the Float Switch.
5) Take off the Hose sleeving the Float Switch leads.
6) Sleeve the leads of the new Float Switch with the Hose.
7) Install the new Float Switch, and replace the removed parts in the reverse order of
which they were removed.
8) Go through the steps 12) through 14) in "13. REMOVAL AND REPLACEMENT OF
PUMP MOTOR."

15. REMOVAL AND REPLACEMENT OF SPRAY TUBE

1) Turn off the power supply, and unplug the icemaker.
2) Remove the Top Panel and Top Insulation.
3) Disconnect the Hoses.
4) Lift off the Spray Tube.
5) Install the new Spray Tube.
Note: Place the Spray Tube so that the holding tabs on both sides are in position.
6) Connect the Hoses.
7) Replace the Top Insulation and Top Panel in their correct positions.
8) Plug in the icemaker, and turn on the power supply.