Removal And Replacement Of Dispense Switch; Removal And Replacement Of Solenoid - Hoshizaki DKM-500BAH Service Manual

Crescent cube icemaker / dispenser
Hide thumbs Also See for DKM-500BAH:
Table of Contents

Advertisement

10) Install the new gear motor, assembling the removed parts in the reverse order of the
above procedure.
Note:
• When weight (2.2 Ib) is applied to the chain at the center, the displacement must be
0.31 to 0.51".
• Lubricant (Class SAE 20) must be applied to the chain using a cloth.
11) Replace the panels in their correct positions.
12) Turn on the power supply.
O. Removal and Replacement of Dispense Switch
1) Turn off the power supply.
2) Remove the front panel. Be sure to disconnect the dispense switch connector from the
control box when removing the front panel.
3) Remove the dispense switch assembly.
4) Install a new dispense switch.
5) Replace the front panel in its correct position.
6) Turn on the power supply.
P. Removal and Replacement of Solenoid
1) Turn off the power supply.
2) Remove the panels. Be sure to disconnect the dispense switch connector from the
control box when removing the front panel.
3) Disconnect the connectors from the solenoid leads.
4) Remove the solenoid, and install a new solenoid.
5) Connect the connectors to the solenoid leads.
6) Replace the panels in their correct positions.
7) Turn on the power supply.