3. LOW ICE PRODUCTION

PROBLEM
[1] Freeze cycle
a) See chart 1 - [3], and check dirty Air Filter or Condenser, ambient or water
time is long.
temperature, water pressure or refrigerant charge.
b) See chart 2 - [1], and check Float Switch, Water Solenoid Valve or Controller
[2] Harvest cycle
a) See chart 2 - [2], and check Controller Board, Thermistor, Evaporator, ambient
time is long
and/or water temperature, water supply line or Water Solenoid Valve.

4. ABNORMAL ICE

PROBLEM
[1] Small Cube
a) Ice Cube Guide
b) See chart 1 - [5], and check water supply line, Water Solenoid Valve, water system,
[2] Cloudy or
a) See chart 2 - [1] and - [3], and check Float Switch, Water Solenoid Valve,
irregular cube
b) Spray Guide
c) Water Quality

5. OTHERS

PROBLEM
[1] Icemaker will
a) Bin Control
not stop when
Thermostat
bin is filled
with ice.
[2] Abnormal
a) Pump Motor
noise
b) Fan Motor
c) Compressor
d) Refrigerant Lines
[3] Ice in storage
a) Bin Drain
bin often
melts.
POSSIBLE CAUSE
Board.
POSSIBLE CAUSE
1. Out of position.
Pump Motor or Controller Board.
Controller Board, Spray Tubes, water system, refrigerant charge or Expansion
Valve.
1. Dirty.
1. High hardness or contains
POSSIBLE CAUSE
1. Set too cold.
2. Defective.
1. Bearings worn out.
1. Bearings worn out.
2. Fan blade deformed.
3. Fan blade does not move
1. Bearings worn out, or
2. Mounting pad out of
1. Rub or touch lines or other
1. Plugged.
Circulated water falls into
bin.
impurities.
freely.
cylinder valve broken.
position.
surfaces.
36
REMEDY
REMEDY
1. Place in position.
1. Clean.
1. Install a water filter or
softener.
REMEDY
1. Adjust warmer.
2. Replace.
1. Replace.
1. Replace.
2. Replace fan blade.
3. Replace.
1. Replace.
2. Reinstall
1. Replace.
1. Clean.