DIP 2
Set the OPENING and CLOSING movement speed.
After switching DIP2 to ON, select the CLOSING speed indicated by LED LD3 using the PU1 key.
LD3 1 flash
LD3 2 flashes
LD3 steady light
After switching DIP2 to ON, select the OPENING speed indicated by LED LD1.
LD1 1 flash
LD1 2 flashes
LD1 steady light
Slowing down speed is not changed.
CAUTION: At the end of programming switch DIP 2 back to OFF, the service light starts to flash, give a S.S. command, an opening (or
closing) movement is commanded during which operation parameters are updated then, at the end of the movement, the service light
switches off.
DIP 3
Enabling and disabling sharing function.
On: Sharing function enabled.
The S.S. Or transmitter impulse has no effect during the opening phase and during TCA pause.
Off: Sharing function disabled (default).
DIP 4
Disabling of the ESA energy saving function.
With the ESA function enabled once opening or closing movements have been completed, the control unit is in maximum energy
efficiency condition, reducing absorption to minimum and disconnecting accessory outputs.
On: ESA energy saving function disabled.
Off: ESA energy saving function enabled (default).
To prevent the belt from remaining tensioned once the mechanical closing end-of-run is reached, a brief inversion is commanded in the
opening direction. This inversion can be adjusted (or excluded) , if necessary, following this procedure:
- Switch DIP 1 and DIP 2 to ON.
- PU2 selects the duration of the inversion, indicated by LED LD1:
LD1 1 flashing
inversion disabled
LD1 2 flashing
minimum inversion
LD1 3 flashing
medium inversion (Default)
LD1 4 flashing
maximum inversion
CAUTION: After programming, switch DIP 1 and DIP2 to OFF.
Carry out some test movements to check correct operations.
Switching DIP to ON changes the control unit to DEAD MAN mode.
The PHOT input takes on the CLOSE key function (connect key with N.O. contact).
The S.S. input takes on the OPEN key function (connect key with N.O. contact).
The OPEN/CLOSE keys must remain pressed during the movement.
Opening the STOP input stops the motor. Simultaneous pressing of OPEN/CLOSE keys stops the motor.
The control unit is equipped with a built-in radio module to receive ARC rolling-code remote controls, with a frequency of 433.92MHz.
Before using the remote control, please study the information with care, the storage procedure is shown as follows, the device is able
to store up to 64 different codes.
Storage of a transmitter key with S.S. activation
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the key of the transmitter to be stored with S.S. function within 10s, the 3 red LEDs light up for 1s, then, after storing, the
receiver automatically exits the programming phase.
Storing a transmitter key with Partial Opening activation function (10cm).
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key again, the LD1 LED flashes twice with 1s pause
- Press the key of the transmitter you wish to store with Partial Opening function within 10s, the 3 red LEDs light up for 1s then, after
storing, the receiver automatically exits the programming phase.
TCA closure has no effect on the Partial Opening function.
Partial opening can take place only if the panel is completely closed.
To exit programming without storing the transmitter, wait 10s.
Storage of a transmitter key with timed "Service Light" function
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key twice more, the LD1 LED will flash 3 times with 1s pause
- Press the key of the transmitter to be stored with the timed "Service Light" function within 10s, the 3 red LEDs light up for 1s then,
after storing, the receiver automatically exits the programming phase.
The "Service Light" is enabled for 90s each time the stored key is pressed.
12
50% of maximum speed (Default)
75% of maximum speed
maximum speed
50% of maximum speed
75% of maximum speed (Default)
maximum speed
CONFIGURATION OF BUILT-IN RECEIVER

BELT TENSIONING

DEAD MAN MODE
(MANUAL STORAGE)