Fluidwell B Series Quick Reference Manual

Flowrate monitor / totalizer

Advertisement

Quick Links

B-ALERT
Flowrate monitor / totalizer
Quick Reference Guide
B-Series - Basic with a capital B
More info:
www.fluidwell.com
MORE INFORMATION
Downloads:
Detailed user-manual
EU Declaration of Conformity (DoC),
by scanning the QR-code:
or visit our
website:
www.fluidwell.com/bseries.
Fluidwell bv
Voltaweg 23
5466 AZ Veghel - The
Netherlands
www.fluidwell.com
Doc: B-Alert_QRG_02.docx
This publication is subject to change without prior notice.
1. INTRODUCTION
The B-Series are intended for use in safe areas (ordinary locations)
and designed and constructed for measurement purposes in
industrial processes. A hazardous situation may occur if the B-
Series is not used for the purpose it was designed for or is used
incorrectly.
2. DESCRIPTION
The B-Alert is used as a flowrate monitor and indicator / totalizer
and has one flowmeter input and two alarm or scaled pulse outputs.
B-Series components:
• the front cover (3) with the display (5) and the control keys (4);
• the body (1) with knockouts for the cable glands (2).
3. OPERATION
SELECT-key
to view the Flowrate, Total, Accumulated total, alarm
value low and high flowrate.
CLEAR-key
when in the Total screen, to reset (clear) the Total.
Programming flowrate alarm value:
1. Press the SELECT key to view the ALARM screen.
2. Simultaneously, press SELECT + CLEAR.
3. Press SELECT to increase value and CLEAR to select digit.
4. Confirm change: simultaneously press SELECT + CLEAR
You can reset (clear) the Total:
1. Press the SELECT key to view the Total screen.
2. Press the CLEAR key two times.
Examples display information:
Flowrate
Programming low flowrate alarm
4. NAVIGATION IN SETUP MENU
The setup menu has menus (e.g. 1, 2 and 3) and sub-menus
(e.g. 2.1, 2.2 etc.) to configure the B-Series.
Enter / leave setup: press and hold SELECT 7 seconds
Select a menu: press CLEAR
Select a sub-menu: press SELECT
Change selection:
simultaneously, press SELECT + CLEAR.
press SELECT to increase value en RESET to
select the digit or change the selection.
Confirm change: simultaneously press SELECT + CLEAR
5. SETUP MENU STRUCTURE
1.
TOTAL
5.
1.1
Unit
5.1
1.2
Decimals
5.2
1.3
K-Factor
5.3
1.4
K-Factor decimals
5.4
5.5
2.
RATE
2.1
Unit
6.
2.2
Time unit
6.1
2.3
Decimals
6.2
2.4
K-Factor
6.3
2.5
K-Factor decimals
6.4
2.6
Measurement
6.5
3.
ALARM
3.1
Zero
3.2
Low alarm
3.3
High Alarm
4.
METER
4.1
Signal
DIGITAL OUT
Output 1
output 2
Mode
Decimals
Amount
OTHER
Model
Software version
Serial number
Pin code
Backlight

Advertisement

loading

Summary of Contents for Fluidwell B Series

  • Page 1 2. Simultaneously, press SELECT + CLEAR. K-Factor decimals Pin code 3. Press SELECT to increase value and CLEAR to select digit. Measurement Backlight Fluidwell bv 4. Confirm change: simultaneously press SELECT + CLEAR ALARM Voltaweg 23 You can reset (clear) the Total: Zero 5466 AZ Veghel - The 1.
  • Page 2 GENERAL SAFETY INFORMATION 7. GENERAL TECHNICAL SPECIFICATIONS BATTERY SAFETY INSTRUCTION This safety information is meant for guidance. Consult the full Sensor: Coil (30mVpp); Reed; NPN; PNP; NAMUR user-manual for all detailed safety instructions, safety rules and Rating: IP65 precautionary measures. The employer's and the plant owner’s Ambient: -20°C to +60°C (-4°F to +140°F) safety instructions shall always prevail.

This manual is also suitable for:

B-alert