Page 1
INSTALLATION AND OPERATING INSTRUCTIONS HDCS - Floor Mounted Electric Combination Boiler HDCSM - Wall Mounted Electric Combination Boiler...
Page 2
This manual forms an essential part of the product and it must be given to the user. Read the warnings and recommendations in the manual carefully, as they contain important information on the safety, use and maintenance of the installation. These boilers are to be installed by qualified personnel only, following the manufacturer’s instructions.
INDEX Page. LIST OF COMPONENTS ............................2 CONTROL COMPONENTS ................................3 IMPORTANT INFORMATION ................................4 WHO THIS BOOKLET IS FOR ..................................4 RECOMMENDATIONS .................................... 4 APPLICABLE LEGISLATION ..................................4 WARNINGS ..................................... 4 IN STALLATION INSTRUCTIONS ........................... 5 HYDRAULIC INSTALLATION .................................. 6 ELECTRICAL INSTALLATION ..................................
2 CONTROL COMPONENTS 1. DHW thermometer.: 6. Boiler control thermostat: Indicates the DHW temperature Allows you to select the desired heating water temperature 2. DHW general switch. “i”: Turns the Domsetic Hot Water On or Off 3. DHW control thermostat.: 7.
Boiler installation and maintenance must be carried out by qualified technicians, in accordance with applicable legislation.. Flexiheat UK shall hold no liability for any damages caused by incorrect installation or incorrect use of the appliance or accessories. Flexiheat UK reserves the right to modify the technical characteristics and components of its products without prior notice.
HDCS / HDCSM 4.1 Hydraulic installation Choose a location complying with the conditions required by applicable law. If the boiler is located on a lower level than any of the heating water pipes, it is recommended to fit shut-off valves to the flow and return pipes, to avoid having to drain the installation when maintenance work is carried out on the boiler.
5 FIRST START-UP 5.1 Filling the installation Use a filling valve to fill the installation slowly until the pressure shown on the thermo hydrometer is between 1 to 1.5 bar. 5.2 Checking the circulating pump functioning Unscrew the circulating pump cap so that the rotation shaft is visible. Connect the boiler main switch and check if the pump shaft is turning.
HDCS / HDCSM To regulate the room temperature you will need to install a room thermostat. This thermostat switches off the boiler when the selected temperature is reached, and starts it up again when the temperature drops. The boiler is pre-wired for connection of a room thermostat. To do this, remove the bridge from the connector block and connect the room thermostat.
11 DIAGRAMS AND MEASUREMENTS HDCS HDCSM RC VS IC: Heating Output HDCSM 1" H, HDCS 3/4" M. RC: Heating Return, 3/4" M. VS: Pressure relief valve, 1/2" H. EAS: Domestic Cold Water Inlet, 1/2" M. IAS: Domestic Hot Water Outlet , 1/2" M.
HDCS / HDCSM 12 CIRCULATING PUMP FLOW CURVES The graphs below can be used to obtain the hydromotive pressure available in the installation at the boiler output, taking the boiler pressure drop and pump functioning curves into account. These graphs show three curves, corresponding to the three speeds of the circulating pumps and the boiler pressure drop.
HDCS: Pump Curve HDCSM: Pump Curve 13 TECHNICAL CHARACTERISTICS HDCS HDCSM MODEL 45/90 10/15 45/90 10/15 Power 4.5-9 10.5-15 4.5-9 10.5-15 230 V~ 230 V~ Main Supply Voltage 230 V 3~ 400 V 3N~ 230 V 3~ 400 V 3N~ 400 V 3N~ 400 V 3N~ 6x1.5...
HDCS / HDCSM 14.2 Power diagram HDCS-HDCSM 45/90, HDCS-HDCSM 10/15 O 1 L HEATING Heating contactors. Heating element units. Bridges for heating power selection. A, B, C: DHW Resistance group A.C.S.: HDCS-HDCSM 180, HDCS-HDCSM 210 HEATING Heating contactors. Heating element units. DHW Resistance Group A.C.S.:...
14.3 Power cable dimensions The size of the power cables should correspond to the type and calibre of the fuse, which should be chosen according to the boiler’s nominal current. The installation must comply with applicable legislation in all cases. The permissible current for the electric cabling depends on the room temperature, the diameter, length and insulation of the conductors, the type of conduit and the conduit fitting and environment.
HDCS / HDCSM 16.2 HDCSM Pos, Code Description Pos, Code Deescription Lock Spring closure CFER000026 CFER000048 Electric front Right Cover SELEDCS000 SEPO000356 Door Heating element 9 kW (45/90) SEPO000023 CRES000004 Left Side Heating element 15 kW (10/15) SEPO000357 CRES000008 Safety thermal 80 ºC Heating element 18 kW (180) CELC000058 CRES000009...
HDCS / HDCSM 17 Fault Finding In this section we list common faults and solutions FAULT CAUSE REPAIR - The pump does not turn Unblock the pump Purge the installation and - Air in the heating circuit of the boiler RADIA TORS the boiler (The plug of the DO NOT...