v For environments that are not preconfigured, ensure that backup target volumes
Example:
Symptom: VMFS volume that is on recovered devices "xxx" and expected to be
auto-mounted during HBA rescan cannot be found. Figure 42 shows an example
error message of a VMFS volume that is on the recovered devices and expected to
be auto-mounted during HBA rescan, but cannot be found.
Figure 42. Incomplete Recovery
Possible causes and solutions:
v The backup target volumes are not mapped to the VMware ESX servers.
v Some extra time is required to be auto-mounted. Increase the value of parameter
Note: You might also need to increase the storage.commandTimeout value of
VMware SRM appropriately.

Reprotect failures

Verify the following items when you encounter failure during Reprotect operations:
v The user name and password for both the protected (primary) and the recovery
58
IBM DS8000 Storage Replication Adapter
are mapped to the VMware ESX servers successfully at the recovery (secondary)
site.
– For environments that are preconfigured, check whether pre-created backup
target volumes are pre-mapped to the VMware ESX servers at the recovery
site.
– For environments that are not preconfigured, check and correct host
connections of the recovery site DS8000.
WaitExtraSeconds in Windows Registry HKEY_LOCAL_MACHINE\SOFTWARE\
Wow6432Node\IBM Corporation\IBM DS8000 Storage Replication Adapter. This
parameter makes DS8000 SRA wait extra time before it responds to SRM.
(secondary) site DS8000 device's HMC are the same.