Summary of Contents for IBM 64-bit/66MHz PCI ATM MMF
Page 1
64-bit/66MHz PCI ATM MMF Adapter Installation and Using Guide SA23-1269-00...
Page 2
A reader’s comment form is provided at the back of this publication. If the form has been removed, address comments to Publications Department, Internal Zip 9561, 11400 Burnet Road, Austin, Texas 78758-3493. To send comments electronically, use this commercial internet address: aix6kpub@austin.ibm.com. Any information that you supply may be used without incurring any obligation to you.
Trademarks . . ix Chapter 1. Overview . Software Requirements . Chapter 2. Installing the ATM 155 Software and the 64-bit/66MHz PCI ATM MMF Adapter Preparing to Install the ATM 155 Software . Installing the ATM 155 Software Installing the Adapter .
Page 4
Diagnostics . . 23 Troubleshooting . 23 Appendix D. Product Features and Specifications . . 25 Features . . 25 Specifications . . 26 Installation and Using Guide...
Safety Information DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system. It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock.
Handling Static-Sensitive Devices Attention: Static electricity can damage the device and your system unit. To avoid damage, keep this device in its anti-static protective bag until you are ready to install it. To reduce the possibility of electrostatic discharge, follow the precautions listed below: v Limit your movement.
(ATM), networking, and AIX Version 4.3.3, as well as AIX Version 5.1.0 and later. It provides instructions to install the 64-bit/66MHz PCI ATM MMF Adapter with AIX and with ATM 155 software. Instructions include directions to configure the 64-bit/66MHz PCI ATM MMF Adapter.
64-bit/66MHz PCI ATM MMF Adapter. Software Requirements The 64-bit/66MHz PCI ATM MMF Adapter is supported on AIX Version 4.3.3, as well as AIX Version 5.1.0 and later. If support is required on an AIX release other than these versions, ensure that this adapter is supported on that release of AIX prior to installation.
Chapter 2. Installing the ATM 155 Software and the 64-bit/66MHz PCI ATM MMF Adapter This chapter explains how to install the 64-bit/66MHz PCI ATM MMF Adapter with ATM 155 software, as well as how to connect ATM cables. Before proceeding with these instructions, it is recommended that you read “Chapter 4.
-Cc adapter | grep atm and press Enter. 4. A list of adapters displays. Verify that the 64-bit/66MHz PCI ATM MMF Adapter is in Available mode. If your 64-bit/66MHz PCI ATM MMF Adapter is not available, run the diagnostics utility described in “Appendix C. Troubleshooting and Diagnostics”...
Note: The connector on the adapter conforms with the ATM Forum standard. If your switch connector pinout is not compatible with this standard, obtain or create a cable that conforms to the standard. Chapter 2. Installing the ATM 155 Software and the 64-bit/66MHz PCI ATM MMF Adapter...
“Chapter 4. Managing the Network” on page 13. Configuring the Adapter To configure the 64-bit/66MHz PCI ATM MMF Adapter, do the following: 1. Turn on your system unit power. 2. Log in to the AIX operating system as root user.
– For client connections svc_c, type the 20-byte hexadecimal ARP server ATM address for your system unit and press Enter. (For example, 39.99.99.99.99.99.99.00.00.99.99.02.02.00.00.8d.44.a3.02.03). To obtain your ATM server address, at the command prompt type the following on the ARP server machine and press Enter. arp -t atm -a –...
Configuring PVCs Note: You can configure the 64-bit/66MHz PCI ATM MMF Adapter to use PVCs without configuring SVCs. To configure the 64-bit/66MHz PCI ATM MMF Adapter to use PVCs, do the following: 1. At the AIX command prompt, type: smitty atmpvc and press Enter.
7. If you need to make changes, continue with the next step; otherwise, press F10 to exit SMITTY. 8. From the PVCs for IP over an ATM Network menu, select Change / Show Characteristics of a PVC for IP over an ATM Network. 9.
Page 21
v For DETAILED output? Select yes or no. 15. The ARE YOU SURE? screen displays: v To continue to remove the software, press Enter. v To cancel the uninstallation process, press F3. 16. When removal is complete and the Command status in the Command Status screen changes from running to OK, press F10 to exit SMITTY.
5-byte header, while the VCI field occupies 2 bytes in the ATM cell’s 5-byte header. For the 64-bit/66MHz PCI ATM MMF Adapter, the value of VPI must be 0. The VCI value can be between 0 and 127 decimal.
Changing ATM Adapter Characteristics The 64-bit/66MHz PCI ATM MMF Adapter characteristics are automatically set during system boot, and these settings provide optimum performance. If you are an experienced user and want to change the adapter characteristics, use the following...
Page 25
4. Change any values in the Change / Show Characteristics of an ATM Adapter screen and press Enter. v Device name – atm0 (read-only) v Description – 64-bit/66MHz PCI ATM MMF Adapter v Status – Defined (read-only) v Location – 00-01 (read-only) v Enable ALTERNATE ATM MAC address –...
Appendix A. Communications Statements The following statement applies to this product. The statement for other products intended for use with this product appears in their accompanying documentation. Federal Communications Commission (FCC) Statement Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Responsible Party: v International Business Machines Corporation v New Orchard Road v Armonk, New York 10504 v Telephone: (919) 543-2193 Tested to Comply With FCC Standards FOR HOME OR OFFICE USE European Union (EU) Statement This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
Radio Protection for Germany Dieses Gerät ist berechtigt in Übereinstimmung mit dem deutschen EMVG vom 9.Nov.92 das EG–Konformitätszeichen zu führen. Der Aussteller der Konformitätserklärung ist die IBM Germany. Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse B. Appendix A. Communications Statements...
Appendix B. Notices This information was developed for products and services offered in the U.S.A. The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturer’s representative for information on the products and services currently available in your area. Any reference to the manufacturer’s product, program, or service is not intended to state or imply that only that product, program, or service may be used.
2. Disconnect and reconnect all 64-bit/66MHz PCI ATM MMF Adapter cables. 3. Remove and reseat the adapter. 4. Install the 64-bit/66MHz PCI ATM MMF Adapter in a different slot if one is available. 5. After completing steps 1 through 4, refer to your system unit documentation to reassemble your system unit and reconnect the power cord.
Appendix D. Product Features and Specifications Following is an overview of the 64-bit/66MHz PCI ATM MMF Adapter features and a list of product specifications. Features The 64-bit/66MHz PCI ATM MMF Adapter for AIX provides direct access to ATM networks, and dedicated 155 Mbit/sec full-duplex connection using PVCs or SVCs while enabling TCP/IP to run over an ATM network.
Specifications The adapter complies with applicable ATM Forum and PCI bus specifications. Environment Power dissipation Maximum 8 W Power VCC 4.75 to 5.25 V Operating temperature 10 to 60 °C Humidity 8 to 80% noncondensing PCI Interface Size 6.2″ x 3.0″ single-slot adapter Bus master 64-bit bus master capability Installation and Using Guide...
Page 37
No Thank you for your responses. May we contact you? When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you.
Page 38
Readers’ Comments — We’d Like to Hear from You Cut or Fold Along Line SA23-1269-00 Fold and Tape Please do not staple Fold and Tape _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NO POSTAGE NECESSARY IF MAILED IN THE...
Page 40
Part Number: 09P2181 Printed in the United States of America on recycled paper containing 10% recovered post-consumer fiber. SA23-1269-00...