2.
Set the discharge current, and press [Enter].
0.0000V
CURRENT= 7.000A
3.
Set the discharge stop voltage, and press [Enter].
0.0000V
STOP VOLT= 35.00V
4.
Set the discharge stop capability, and press [Enter].
0.0000V
STOP CAP= 11.000AH
5.
Set the discharge time, and press [Enter].
0.0000V
STOP TIMER= 99999S
Save the battery test to specified file (1 – 10). After the file number is set,
6.
press [Enter].
0.0000V
SAVE BATT FILE 2
Set the power on state to the battery test. The steps are as follows.
1.
Press [Shift]+ [8] (system) to enter into system menu.
0.0000V
POWER-ON
2.
Press right key, select RUNMODE and confirm with [Enter] button.
0.0000V
RUN NORMAL
3.
Press
The VFD displays the battery test page.
0.0000V
4.
After above steps, press [.] (Trigger) button to run BATT_TEST file.
The discharging process will be terminated automatically when stop
conditions are reached.
Battery Test Data Recalling
Applicable to IT8511B+/IT8512+/IT8512B+/IT8512C+/IT8512H+/IT8514C+
models. The steps are as follows:
1.
In the BATTERY mode, press [Shift]+ [Enter] (Recall).
0.0000V
RECALL BATTERY 1
2.
Press the number keys to select the existing BATT_TEST file and press
[Enter].
0.000A
0.000A
0.000A
0.000A
0.000A
0.000A
BUZZER
0.000A
to select BATTERY, press [Enter] to confirm.
0.000A
0S 0.000AH
Note
To exit the BATTERY mode, you can press the [Shift]+ [8] (System)
buttons to enter the system menu and set the RUNMODE to
NORMAL.
0.000A
Copyright © Itech Electronic Co., Ltd.
Functions and Characteristics
36
Need help?
Do you have a question about the IT8500plus Series and is the answer not in the manual?
Questions and answers