Meler Micron+ Series Instruction Manual

Annex communications modbus/profibus/ethernet ip/profinet
Hide thumbs Also See for Micron+ Series:

Advertisement

Quick Links

GLUING SOLUTIONS
ANNEX
INSTRUCTIONS
MANUAL
COMMUNICATIONS
MICRON + SERIES
ModBus / ProfiBus
EtherNet IP / ProfiNet
MA-5177-ENG 040320

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Micron+ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Meler Micron+ Series

  • Page 1 GLUING SOLUTIONS ANNEX INSTRUCTIONS MANUAL COMMUNICATIONS MICRON + SERIES ModBus / ProfiBus EtherNet IP / ProfiNet MA-5177-ENG 040320...
  • Page 2 The specifications and information contained in this manual may be modified without prior notice. This manual is a translation of the original that was written by Focke Meler Gluing Solutions, S. A. in spanish language. If there is any discrepancy between the different versions of this manual, the original written in the spanish language shall prevail.
  • Page 3: Table Of Contents

    ANNEX COMMUNICATIONS MICRON + SERIES TABLE OF CONTENTS MA-5177-ENG TABLE OF CONTENTS 1. SAFETY GUIDELINES General Symbols Mechanical components Electrical components Hydraulic components Pneumatic components Thermal components Materials Noise emission declaration Intended use Limited use 2. MODBUS Main components Enable Modbus communications Communication protocols Connections 3.
  • Page 4 FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS 4. PROFINET Main components Connecting the communications cable Enable Modbus communications Communication protocols Connections Node Name Configuration PLC configuration. GSDML file 5. PROFIBUS Main components Connecting the communications cable Enable Modbus communications Communication protocols...
  • Page 5: Safety Guidelines

    ANNEX COMMUNICATIONS MICRON + SERIES SAFETY GUIDELINES MA-5177-ENG 1. SAFETY GUIDELINES General The information contained in this section applies not only to everyday equipment operation, but also to any procedure carried out on it, whether for preventive maintenance or in the case of repairs and the replacement of worn out parts.
  • Page 6: Mechanical Components

    FOCKE MELER GLUING SOLUTIONS SAFETY GUIDELINES Mechanical components The hot-melt installation, which is installed to this device, requires moving parts that can cause damage. Use the equipment correctly, and do not remove the safety guards while the equipment is in operation; prevent the risk of possible entrapment due to moving mechanical parts.
  • Page 7: Thermal Components

    Safety Information Sheet of the adhesive. Materials Meler systems are designed for use with hot-melt adhesives. They should not be used with any other type of material, and especially not with solvents, which may cause personal injury or damage to internal system components.
  • Page 8: Intended Use

    Note: Do not modify the equipment or use components that were not supplied by Meler. For any modification of a component of the equipment or part of the installation, you must firstly consult the After-Sales Service...
  • Page 9: Modbus

    See point “6. Communication data table” in this manual to see the full list of functions. For more information about the communications gateway, please contact our After-Sales Service or your Meler Sales Agent. Main components 1. DB9 external connector (pre-installed).
  • Page 10: Enable Modbus Communications

    FOCKE MELER GLUING SOLUTIONS ANEXO COMUNICACIONES TÓN MICRON+ PISTÓN MICRON+ PISTÓN Enable Modbus communications : S02001100 v1.0.106 : S02001100 v1.0.106 : S02200100 v1.0.084 : S02200100 v1.0.084 : S02102100 v1.0.106 : S02102100 v1.0.106 2. Extra Settings Menu 2.2 Extra Settings Sound on alarm...
  • Page 11: Ethernet Ip

    ETHERNET IP MA-5177-ENG 3. ETHERNET IP Optionally, units in the Micron+ series may come with an Ethernet IP communications gateway installed inside the unit. This connection makes it possible to read and write the most important parameters for the unit’s functionality.
  • Page 12: Connecting The Communications Cable

    FOCKE MELER GLUING SOLUTIONS ETHERNET IP Connecting the communications cable Warning: Risk of electrical shock. Carelessness may produce injury or death. 1. Turn off the melter. 2. To remove the casing from the machine, first you have to separate the electrical cabinet from the tank.
  • Page 13: Enable Modbus Communications

    ANNEX COMMUNICATIONS MICRON + SERIES ETHERNET IP MA-5177-ENG TÓN MICRON+ PISTÓN MICRON+ PISTÓN Enable Modbus communications : S02001100 v1.0.106 : S02001100 v1.0.106 : S02200100 v1.0.084 : S02200100 v1.0.084 : S02102100 v1.0.106 : S02102100 v1.0.106 2. Extra Settings Menu 2.2 Extra Settings Sound on alarm Screen saver 10 min...
  • Page 14: Ip Address Setting

    PLC configuration. EDS file To configure the machine with Ethernet IP communications in the PLC, it is necessary to include the EDS file supplied by Meler in the project. You can also download the most current version on the gateway manufacturer’s website...
  • Page 15: Profinet

    ANNEX COMMUNICATIONS MICRON + SERIES PROFINET MA-5177-ENG 4. PROFINET Optionally, units in the Micron+ series may come with an Profinet communications gateway installed inside the unit. This connection makes it possible to read and write the most important parameters for the unit’s functionality.
  • Page 16: Connecting The Communications Cable

    FOCKE MELER GLUING SOLUTIONS PROFINET Connecting the communications cable Aviso: Riesgo de recibir sacudidas eléctricas. La falta de atención puede provocar lesiones o la muerte. 1. Turn off the melter. 2. To remove the casing from the machine, first you have to separate the electrical cabinet from the tank.
  • Page 17: Enable Modbus Communications

    ANNEX COMMUNICATIONS MICRON + SERIES PROFINET MA-5177-ENG TÓN MICRON+ PISTÓN MICRON+ PISTÓN Enable Modbus communications : S02001100 v1.0.106 : S02001100 v1.0.106 : S02200100 v1.0.084 : S02200100 v1.0.084 : S02102100 v1.0.106 : S02102100 v1.0.106 2. Extra Settings Menu 2.2 Extra Settings Sound on alarm Screen saver 10 min...
  • Page 18: Node Name Configuration

    PLC configuration. GSDML file For the configuration of the machine with Profinet communications in the PLC, it is necessary to include the GSDML file supplied by Meler in the project. You can also download the most current version on the gateway manufacturer’s...
  • Page 19: Profibus

    PROFIBUS MA-5177-ESP 5. PROFIBUS Optionally, units in the Micron+ series may come with an Profibus communica- tions gateway installed inside the unit. This connection makes it possible to read and write the most important para- meters for the unit’s functionality.
  • Page 20: Connecting The Communications Cable

    FOCKE MELER GLUING SOLUTIONS PROFIBUS Connecting the communications cable Aviso: Riesgo de recibir sacudidas eléctricas. La falta de atención puede pro- vocar lesiones o la muerte. 1. Turn off the melter. 2. To remove the casing from the machine, first you have to separate the electrical cabinet from the tank.
  • Page 21: Enable Modbus Communications

    ANEXO COMUNICACIONES EQUIPOS FUSORES MICRON + PROFIBUS MA-5177-ESP TÓN MICRON+ PISTÓN MICRON+ PISTÓN Enable Modbus communications : S02001100 v1.0.106 : S02001100 v1.0.106 : S02200100 v1.0.084 : S02200100 v1.0.084 : S02102100 v1.0.106 : S02102100 v1.0.106 2. Extra Settings Menu 2.2 Extra Settings Sound on alarm Screen saver 10 min...
  • Page 22: Connections

    PLC configuration. GSD file To configure the machine with Profibus communications in the PLC, it is necessary to include the GDS file supplied by Meler in the project. You can also download the most current version on the gateway manufacturer’s website...
  • Page 23: Communication Data Table

    ANNEX COMMUNICATIONS MICRON + SERIES COMMUNICATION DATA TABLE MA-5177-ENG 6. COMMUNICATION DATA TABLE The data tables are as follows:: Address Description MAGNITUDE Read / Write TYPE Always number 0x1234 0x1234 uint16 Software Version HMI number 65535 uint16 General device Status number uint16 Temperature OK...
  • Page 24 FOCKE MELER GLUING SOLUTIONS COMMUNICATION DATA TABLE Address Description MAGNITUDE Read / Write TYPE Temperature Setpoint Gun 5 ºC R / W Uint16 Temperature Setpoint Hose 6 ºC R / W Uint16 Temperature Setpoint Gun 6 ºC R / W...
  • Page 25 ANNEX COMMUNICATIONS MICRON + SERIES COMMUNICATION DATA TABLE MA-5177-ENG Address Description MAGNITUDE Read / Write TYPE Common: Hour number R / W uint16 Common: Minute number R / W uint16 Common: Seconds number R / W uint16 Shooting Ctrl: Photocells status number uint16 Shooting Ctrl: Electrovalves status...
  • Page 26 FOCKE MELER GLUING SOLUTIONS COMMUNICATION DATA TABLE Values: 2 ---------0: OFF // 1: HEATING // 2: TEMP OK DELAY // 3: STANDBY // 4: INHIBITED // 5: ERROR // 6: READY // 7: UNKNOWN 3 ---------0: No_Ok // 1: Ok...
  • Page 27: Spare Parts List

    ANNEX COMMUNICATIONS MICRON + SERIES SPARE PARTS LIST MA-5177-ENG 7. SPARE PARTS LIST The list of the most common spare parts appears in this section, providing a quick and reliable guide to choosing them. The spare parts are grouped together naturally, in the same way as they are located in the melters.
  • Page 28 FOCKE MELER GLUING SOLUTIONS SPARE PARTS LIST This page is intentionally left blank.
  • Page 29: Communications Gateway

    ANNEX COMMUNICATIONS MICRON + SERIES SPARE PARTS LIST MA-5177-ENG A. COMMUNICATIONS GATEWAY Nº Ref. Denomination 150130530 Communications gateway Ethernet IP AB7072 150130540 Communications gateway Profinet AB7013 150130660 Communications gateway Profibus AB7000...