Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
Figure 5: Replacing the Air Filter
Step 4
Replace the air filter with a new one if the air filter is dirty or clogged with dust.
Step 5
Attach the cable guide and insert the air filter into the shelf assembly.
Note
Step 6
Tighten the screw on the air-filter.
Stop. You have completed this procedure.
NTP-G262 Replace the Air Filter of the ONS 15454 M6 Shelf
Assembly
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The air filter must be inserted with the grid facing the shelf assembly as shown in
the Air Filter, on page
7.
This procedure replaces the air filter of the ONS 15454 M6 shelf assembly.
New air filter
•
NTP-G252 Install the ONS 15454 M6 Shelf
• Connect the chassis to the office ground. For detailed instructions on how
to ground the chassis, refer to the
Guide for Cisco CPT and Cisco ONS Platforms
As Needed
Remote
Provisioning or higher
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf