Pilot Air PAC Series Users Maintenance And Spare Parts Manual page 32

Table of Contents

Advertisement

DRAIN CONDENSATE (fig. 5)
-
The oil/air mixture cooling is set at a higher
temperature with respect to the dew point of the
air (under standard operating conditions of the
compressor). However, the condensate in the oil
cannot be fully removed.
-
Blow off compressed air through cock B and
then close it as soon as oil begins to flow out
instead of water. Check the oil level and top up if
necessary.
-
CONDENSATE IS A POLLUTING MIXTURE! It
must not be let into the sewage.
OIL CHECK AND TOP UP IF NECESSARY (Fig. 5)
-
With the compressor off, check the oil level by
means of the warning indicator positioned on the
tank.
-
If the level is under minimum, remove the front
panel and refill through hole A.
-
Quantity of oil for refilling from the min to the max level = 7 litres.
-
Use ONLY oil of the same type (RotEnergy Plus).
CLEANING/REPLACING THE FILTERING
ELEMENT (Fig. 6)
-
Open the front panel, unhook the clips and
remove the cover G. Extract the filtering
element C.
-
Clean them using compressed air, acting
from the inside towards the outside.
-
Control, against the light, for the presence of
splits: in this case replace filters.
-
The filtering elements and the cover must be
assembled carefully so as not to allow the
passage of dust into the compressor unit.
-
Never allow the compressor to function
without the filtering element.
CLEANING THE RADIATOR
It is recommended that in case of over temperature
anomalies and however, at least once a year that the radiator is cleaned.
Proceed as follows:
-
position a sheet of protective plastic under the radiant pack;
-
spray (with a washing + detergent gun) from outside towards the inside;
-
check that the air flows correctly by means of the radiator.
32 |
P a g e
Maintenance
PLUS 56-75-Cod.197DD8805