Fan temperature hysteresis : Defines the delta temperature in which the main cooling fan must work.
Diagnostic
Input
Output
AN1
AN2
AN3
INV
Keeping the I key pressed, you can execute a motor start-up test. Pressing the 0 key, you can upload the default
parameters (there are 32 sets of parameters present). The Factory password is required.
Press the RESET key to execute calibration of the pressure transducer (the factory password is required)
Output Configuration : Sub-menu that allows you to associate the outputs CN4-8 and CN4-9 with a function,
choosing from: "Pre-alarm", "Control ON", "Compressor ON", "Motor Running" and "Compress No Load/Loaded"
Comp. rotation man. : to define.
Dryer
Condensate drainage: Sub-menu for dryer configuration (see CONDENSATE DRAINAGE MENU paragraph).
25 |
P a g e
Start-Up and Operation
: Using the diagnostic menu, you can control the various inputs and outputs of the control
unit.
: The status of 9 digital inputs can be controlled
: Using the right and left keys, you can move on the relay output you want to command,
while using the up and down buttons to activate the output
: Indicates pressure in bar with centesimal precision
: Indicates the temperature in °C Screw probe
: Indicates the temperature in °C Dryer probe
: Indicates the inverter output automatically switches 4-20mA
: Sub-menu for dryer configuration (see DRYER MENU paragraph).