Download Print this page

quiko QK-CE24BATR Quick Manual

Advertisement

Quick Links

WARNING: After learning the first code the system will only accept that code family (if the first is Rolling all the others will
have to be Rolling).
MEMORY RESET
For cancelling all codes, press and hold the P1 button (red led prog will turn on) until the LED turns off again. When the
button is released, the LED flashes.
WORKING TIME SETUP FOR 2 LEAFS GATES
MAKE SURE THE GATE IS CLOSED
SET DIP10 SW1 TO OFF
Turning the DIP1 SW1 to "ON" enables the self-learning timing:
Pressing the START or the first channel of a previously learned remote control starts opening the gate (otherwise reverse
the terminals 1-2 and 3-4 wires). From this point on, the microprocessor starts to count the working time (programming
LED lights up)
The first leaf starts opening, after desired displacement time, press the TX to start the second leaf, when the first leaf
arrives at the desired position, give another "START" command and it stops. When the second leaf arrives In the desired
position give another "START" command and it also stops (if electrical or mechanical limit switches are used and obstacle
sensing is enabled, there is no need to give a start impulse when the leafs have opened). Flashing lamp lights off and
from this moment the board counts the automatic closing time. When you think enough pause time has passed, press
"START": the second leaf start closing, once the displacement time has passed, give another START signal and also the
first leaf starts closing. When the second leaf arrives at the desired position give another "START" command to stop it.
When the first leaf arrives at the desired position give another "START" command and it also stops (if electrical or
mechanical limit switches are used and obstacle sensing is enabled, there is no need to give a start impulse when the leaf
has closed). The flashing lamp lights off. Programming LED flashes. It is necessary at this point to put the DIP1 to the
"OFF" position (the LED goes off). Now everything is ready to be able to start the opening gate again.
The control unit is also designed to handle the partial opening (pedestrian) via the 2nd channel of the remote control,
previously memorized, or the PEDESTRIAN START input.
To program the pedestrian time, repeat setup as above using the pedestrian start input or the 2
TX.
WORKING TIME SETUP FOR 1 LEAF GATES
MAKE SURE THE GATE IS CLOSED
SET DIP10 SW1 TO ON
Turning the DIP1 SW1 to "ON" enables the self-learning timing:
Pressing the START or the first channel of a previously learned remote control starts opening the gate (otherwise reverse
the terminals 1-2). From this point on, the microprocessor starts to count the working time (programming LED lights up)
The leaf starts opening. When it arrives at the desired position, give another "START" command and it stops. (if electrical
or mechanical limit switches are used and obstacle sensing is enabled, there is no need to give a start impulse when the
leaf has opened). Flashing lamp lights off and from this moment the board counts the automatic closing time. When you
think enough pause time has passed, press "START": the leaf start closing. When it arrives at the desired position give
another "START" command and it stops (if electrical or mechanical limit switches are used and obstacle sensing is
enabled, there is no need to give a start impulse when the leaf has closed). The flashing lamp lights off. Programming
LED flashes. It is necessary at this point to put the DIP1 to the "OFF" position (the LED goes off). Now everything is ready
to be able to start the opening gate again.
-------------------------------------------------- -------------------------------------------------- --------------------------------------------------
WARNINGS
When wiring and inserting the Radio Module, the equipment must not be powered.
The use of this equipment must strictly follow and comply with the technical standards of reference. Installation and / or
maintenance must only be carried out by qualified personnel in accordance with applicable laws. The manufacturer can
not be held liable for any damage caused by improper use and / or unreasonable use. Improper installation or incorrect
use of the product may compromise the safety of the system, all the materials present in the packaging must not be left to
the reach of children as a source of danger.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DISPOSAL: keep the product out of the reach of children. Do not throw the 'apparatus together with ordinary municipal waste as a symbol
marked on the product. (European Directive 2002/96/EC)
And 'the responsibility of the owner dispose of electrical product collection centers according to the specifications of public bodies.
EC DECLARATION OF CONFORMITY '
Below, we declare that the product meets all the requirements for the type of product required by the regulations and directives 2004/108/EC,
2006/95/EC, through the use of standards published in the Official Journal of the European community:
SFT norm: EN 60950:2006
Norma SFT:
EMC norm: EN301489-3 V1.4.1
EMC standard:
It also declares that it is forbidden to put the above-mentioned products on the market before the machine has these rules and it is found to
comply with the conditions required by Directive 89/392 EEC and national laws applies, that is, until the material, to which this declaration ,
does not form a whole with the final machine.
www.quikoitaly.com
Made in Italy
The QK-CE24BATR electronic equipment is designed for automation of LOW VOLTAGE 12V or 24V DC motors. For
swinging and sliding gates.
INSTALLATION NOTES
1) Before proceeding with installation, a thermal or differential magnet switch with a maximum capacity of 10A must be set
upstream of the system. The switch must ensure omnipolar separation of the contacts, with an opening distance of at
least 3 mm
2) Differentiate and separate power cables (minimum section 1.5mm2) from signal cables that can be 0.5mm2.
nd
button of the
SIGNAL LED'S:
All inputs on the M2 terminal block
are filtered by optoisolators that
eliminate low voltage disturbs. If a
dip-switch input is excluded, the
corresponding LED will not light
up, but if it is not connected to a
terminal block with a bridge on the
"com", this will light up.
TECHNICAL FEATURES
- 12Vac or 24Vac electronic board power
supply
- 230Vac toroidal transformer supply
- 12Vcc electric lock
- Courtesy light 12Vdc or 24Vdc
- No. of motors: 1 or 2 Max 150W total
- Battery 12Vdc or 24Vdc
- Flashing: 12Vdc or 24Vdc
- 12Vdc or 24Vdc lamp
- Photocells: 12Vdc or 24Vdc
- Operating temperatures -20 + 55 ° C
QK-CE24BATR
V02
CAUTION: For 24V systems, if a transformer other than that
provided by the factory (recommended) is used, the power
Of the output on the secondary must NOT exceed 24 VAC.
The power output must NOT be less than 150VA

Advertisement

loading

Summary of Contents for quiko QK-CE24BATR

  • Page 1 For cancelling all codes, press and hold the P1 button (red led prog will turn on) until the LED turns off again. When the QK-CE24BATR button is released, the LED flashes. The QK-CE24BATR electronic equipment is designed for automation of LOW VOLTAGE 12V or 24V DC motors. For WORKING TIME SETUP FOR 2 LEAFS GATES swinging and sliding gates.
  • Page 2 CONNECTIONS TO TERMINAL BLOCKS 1 .. MOTOR 1 POSITIVE INPUT N.1 (pedestrian) OBSTACLE SENSING ADJUSTMENTS (default set to half threshold) 2 .. MOTOR 1 NEGATIVE INPUT N.1 (pedestrian) Rotating the PT1 and PT2 trimmer clockwise increases the obstacle sensing of the respective motor. (From 0.5 to 7.0 A). 3 ..