50 amp Service (optional)
On some larger coaches, with more appliances installed, it requires more
120-volt AC power to operate. Availability of 50 amp service is the best
method of providing the owner with an increase of incoming power. 50
amp service is required for coaches with a second air conditioner.
Distribution of power is accomplished in this manner. There will be 2—50
amp main breakers coming into the distribution box to supply your coach.
On each side is the 20 amp breaker feeding the air conditioners as
required. The remaining 6 to 12 breakers will feed the remaining
appliances as marked on attached label. Quantity of breakers depends
on the floor plan, options and size of coach. VENTURE RV recommends
against using any reducer adaptor (50 to 30 or 30 to 15) when 50 amp
service is not available. When using such an adaptor, you have reduced
incoming power and CANNOT power all your appliances. Should you
attempt to draw more power than adaptor can handle, it will overheat,
melt and cause a fire hazard.