Malfunction/Service Signal
If any malfunction is detected, the Gas LED will remain off and the
Operational/CO LED will alternate Red/Green and the alarm will sound
once every 15 seconds. Press the Test/Mute button. If the Test/Mute
button does not clear signals, check the battery voltage. If the battery
voltage is not low and the unit will not return to normal operation,
immediately remove the alarm and return for service or warranty
replacement.
OPERATION
NORMAL
CO ALARM
PROPANE ALARM
ALARM
MALFUNCTION
END OF LIFE
End of Life Signal—5 year Service Life
All 35 series models include an End of Life (EOL) signal indicating the
sensor has reached the end of its service life and you MUST replace the
alarm. The signal is the LED flashing RED RED GREEN GREEN with a
beep every 25-30 seconds. The EOL Signal may be reset by pushing
TEST/RESET button on the alarm. This will reset the EOL Signal for a
period of 72 hours (3 days) for a total of 30 days. After 30 days the signal
cannot be reset and the alarm MUST be replaced. DO NOT
DISCONNECT THE ALARM UNTIL YOU HAVE A REPLACEMENT
ALARM AVAILABLE TO INSTALL.
Smoke Alarm
Smoke alarms are required when propane is in coach and open flame
cooking happens. Alarm is placed on ceiling between bed room and
kitchen. Power to operate is supplied by a 9-volt battery inside the alarm.
AUDIBLE SIGNAL
NONE
4 "BEEPS"
5 SECONDS OFF
CONSTANT
"BEEP" EVERY
30 SECONDS
"BEEP" EVERY
30 SECONDS
LIMITATIONS OF CO AND GAS ALARMS
This alarm will not work without power.
Some reasons for no alarm power are: a blown or missing
fuse, broken wire, faulty wire connection or circuit breaker,
discharged battery, cut lead wires, or improper supply (+) or
ground (-) connections.
32
VISUAL SIGNAL
STEADY GREEN
STEADY RED
FLASHING RED
ALTERNATING
RED/GREEN
RED/RED
GREEN/GREEN