The labeling of safety messages is explained in the chapter Safety. 1.1.4 Used Terminology PC Card cifX Communication Interfaces of the cifX family of Hilscher based on the netX technology. CIFX 50-RE Example for the product name for a PC card cifX Real-Time Ethernet.
Page 15
2. Adjust the configuration of your PROFINET IO Controller device. Use the new GSDML file in the configuration software of the PROFINET IO Controller for this: GSDML-V2.3-HILSCHER-CIFX RE PNS-20130301.xml. 3. Update the PROFINET IO Device firmware in your device to version 3.5.
Page 16
2. Adjust the configuration of your EtherCAT Master device. Use the new XML file in the configuration software of the EtherCAT Master for this: Hilscher CIFX RE ECS V4.2.X.xml. 3. Update the EtherCAT Slave firmware in your device to version 4.2.
CIFX 50E-RE\ET, the Hilscher CIFX RE ECS V4.2.X.xml is provided. CIFX 70E-RE, CIFX 70E-RE\MR, Note! If the XML file Hilscher cifX RE ECS V2.2.x.xml is used/re-installed, the firmware CIFX 100EH- must be used/re-installed at the Version 2.5.x. RE\CUBE EtherNet/IP Adapter (Slave) HILSCHER CIFX-RE EIS V1.1.EDS...
There is no entitlement to revisions of delivered documents. The manual delivered with the product applies. Hilscher Gesellschaft für Systemautomation mbH is not liable under any circumstances for direct, indirect, incidental or follow-on damage or loss of earnings resulting from the use of the information contained in this publication.
19/223 1.3.3 Exclusion of Liability The software was produced and tested with utmost care by Hilscher Gesellschaft für Systemautomation mbH and is made available as is. No warranty can be assumed for the performance and flawlessness of the software for all usage conditions and cases and for the results produced when utilized by the user.
Description The PC Cards cifX are communication interfaces of the cifX product family of Hilscher on the basis of the communication controller netX 100 for the Real-Time Ethernet or fieldbus communication. Depending of the loaded firmware, the protocol specific PC Card cifX proceeds the communication of the corresponding Real-Time Ethernet or fieldbus system.
• For the operating systems Linux, Windows CE, VxWorks, QNX and IntervalZero RTX ™ you can buy Device Driver at the company Hilscher Gesellschaft für Systemautomation mbH http://www.hilscher.com/. 2. The configuration software SYCON.net or alternatively the simple Slave configuration tool netX Configuration Tool must be installed or another application program by which the PC card cifX (Slave) can be parameterized.
Page 41
41/223 System Note If the XML file Hilscher cifX RE ECS V2.2.x.xml is use/updated, the firmware with the version EtherCAT Slave 2.2.x must be use/updated. The loadable firmware supports for the number of cyclic input data and for cyclic output data in total up to 400 bytes.
Table 118: PCI IDs PC Cards cifX on the PCI Bus 10.3 Supported PCI-Bus Commands From the following table you can see which PCI bus commands are supported by the Hilscher PC Cards cifX PCI, PCI Express and Low Profile PCI Express. C/BE3#...
Cards cifX on page 116 (and also the identical values in the data sheet cifX and on the ‘Hilscher Site’) are rounded and unified for the respective types of card. Here the depth of the PC cards PCI (CIFX 50), PCI Express (CIFX 50E) or Low Profile PCI Express (CIFX 70E) has been equated to the rounded width of the front panel.
(e.g. PCI Interface card products) only as part of a machine or machine line or as spare part for such a machine. In case of questions, contact Hilscher and/or your nearest ETG representative. The ETG Vendor-ID policies apply.
Page 219
PROFIBUS and based on RS-485. It usually works with a transmission rate of 187.5 kBaud. netX networX on chip, Hilscher network communication controllers netX Configuration Tool The netX Configuration Tool allows users to operate cifX or netX based devices in different networks.