hilscher CIFX M3042100BM-DP/F User Manual

Pc cards pci express m.2 3042 b-m profibus dp
Table of Contents

Advertisement

Quick Links

User manual
CIFX M3042100BM-DP\F
PC cards PCI Express M.2 3042 B-M PROFIBUS DP
Hilscher Gesellschaft für Systemautomation mbH
www.hilscher.com
DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CIFX M3042100BM-DP/F and is the answer not in the manual?

Questions and answers

Summary of Contents for hilscher CIFX M3042100BM-DP/F

  • Page 1 User manual CIFX M3042100BM-DP\F PC cards PCI Express M.2 3042 B-M PROFIBUS DP Hilscher Gesellschaft für Systemautomation mbH www.hilscher.com DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 2: Table Of Contents

    Diagnosis with LEDs ...................... 23 Overview ........................ 23 System LED ........................ 23 PROFIBUS DP Master.................... 24 PROFIBUS DP Slave..................... 25 Connectors .......................... 26 PROFIBUS interface ...................... 26 CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 3 FCC compliance...................... 37 References........................ 38 Conventions in this manual .................... 40 Legal notes........................ 41 Registered trademarks.................... 45 Licenses ......................... 45 Glossary.......................... 48 Contacts.......................... 49 CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 4: Introduction

    List of revisions Index Date Changes 21-06-29 Manual created. Table 1: List of revisions CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 5: Devices And Accessories

    5/49 2 Devices and accessories The PC card CIFX M3042100BM-DP\F is a communication interface from Hilscher based on the communication controller netX 100 and consists of a basic card that is equipped with a detached network interface. PC card Description of the basic card...
  • Page 6: Basic Card Cifx M3042100Bm

    PCI Express M.2 bus, pin 67 to pin 75 (10) Matrix label Table 4: Legend for the basic card CIFX M3042100BM CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 7: Detached Network Interface Aifx-Dp

    After the download, you can start commissioning and configuring your device immediately. Ø Check our website regularly for software updates for your product. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 8: Revision Or Version Statuses Of The Hardware And Software

    Table 8: Firmware version and file names for permitted protocols Note: Unless otherwise stated, the firmware version in this manual is the same as the stack version. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 9: Device Label With Matrix Code

    The 2D code (Data Matrix Code) contains the following information: Part number: 1234.567 Hardware revision: 1 Serial number: 20000 Figure 3: Example 2D label CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 10: Safety

    Measurement and Analysis of electrical functions and systems · Evaluation of the safety of electrical systems and equipment · Installing and configuring IT systems · CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 11: Safety Messages

    Performing hot-swap or hot-plug may pose a hazard to the PC card, the system platform and the person performing the action. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 12: Property Damage

    If available, use a static-safe workstation. · When not in use, store the equipment in appropriate static-safe packaging. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 13: Power Drop During Write And Delete Accesses In The File System

    Information and data security Take all usual measures for information and data security, in particular, for PC cards with Ethernet technology. Hilscher explicitly points out that a device with access to a public network (Internet) must be installed behind a firewall or only be accessible via a secure connection such as an encrypted VPN connection.
  • Page 14: Warnings

    PC, and make sure you are grounded when you install or uninstall the PC card. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 15: Installing The Hardware

    Operating system ® For SYCON.net for netX: Windows CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 16: Table 10: Panel Cut-Outs And Holes For Mounting Aifx

    When dimensioning the front panel, note the width of the front panel specified in section AIFX-DP [} page 31] . CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 17: Requirements For Operation

    Parameter settings The PC card must be parameterized using the SYCON.net for netX configuration software. Table 11: Requirements for operation CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 18: Overview Installation And Firmware Download

    PC card CIFX M3042100BM-DP\F: Step Description Further information Downloading installation Revision or version · Download the installation files from the Hilscher website for: files statuses of the hardware - cifX Device Driver (latest version) and software [} page 8] - SYCON.net for netX ·...
  • Page 19 Ø To do this, first plug the cable into the cable connector fieldbus X1 on the AIFX-DP. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 20: Figure 4: Connectinge Cable To The Detached Network Interface Fieldbus Aifx-Dp

    Ø Close the housing of the PC or connecting device again. Loading or updating the firmware and configuration in the device Ø Download the firmware from the Hilscher website and save the firmware to your PC's local hard disk. Ø If necessary, transfer the configuration to the PC. Create the configuration using an appropriate configuration software.
  • Page 21: Troubleshooting Information

    LEDs in this manual. For information about the device diagnostics and their functions, see the operating instruction manual of the configuration software for your device. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 22: Uninstall The Hardware

    As a consumer, you are legally obliged to dispose of all waste electronic equipment according to national and local regulations. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 23: Diagnosis With Leds

    Power supply for the device is missing or hardware defect. (off) Table 14: States of the SYS LED, netX 10/50/51/52/100/500-based devices CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 24: Profibus Dp Master

    The LED turns on and off in irregular intervals. acyclic Table 16: LED state definitions for the PROFIBUS DP Master protocol CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 25: Profibus Dp Slave

    (2 Hz) followed by “off” for 250 ms. Table 18: LED state definitions for the PROFIBUS DP Slave protocol CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 26: Connectors

    / out RSTOUT# Reset out (not used) Table 20: Pin assignment for cable connector fieldbus X701 (10FMN-BMT-A-TF), on CIFX M3042100BM CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 27: Pci Express M.2 Bus

    REFCLKP PCIe Reference Clock signals (100 MHz) defined by the PCI Express CEM Specification. Input (not used) Return current path. Power (not used) 59-66 - KEY M CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 28 3.3V 3.3V supply Power Return current path. Power Table 21: Pin assignment PCI Express M.2 bus X200, CIFX M3042100BM CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 29: Technical Data

    10% … 95% relative humidity, no condensation permitted Environment The device must be used only in a pollution degree 2 environment (or better). CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 30: Pci Identifier On The Pci Express M.2 Bus

    Subsystem vendor ID 0x0000 Subsystem device ID 0x0000 Table 23: PCI identifier on the PCI Express M.2 bus for CIFX M3042100BM CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 31: Aifx-Dp

    CE sign CE sign Emission, Immunity Tested together with the corresponding basic card. RoHS Table 24: Technical data AIFX-DP CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 32: Communication Protocols

    'packets' by the host application program. Reference to firmware/stack version Table 25: Technical data PROFIBUS DP Master CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 33: Profibus Dp Slave

    I&M LR services other than ‚Call-REQ/RES‘ are not supported. Reference to firmware/stack 2.11 version Table 26: Technical data PROFIBUS DP Slave CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 34: Dimensions

    The dimensions (L x W x H) given in the section Technical data [} page 29] (or the identical information in the product data sheet or on the Hilscher website) are rounded figures or the respective total measure (for example, including the front panel).
  • Page 35: Dimensions Cifx M3042100Bm

    The height of the component on the top of the basic card M3042100BM does not meet the standard specifications. For more information, see section System requirements [} page 15]. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 36: Dimensions Aifx-Dp

    Dimensions 36/49 Dimensions AIFX-DP Figure 8: AIFX-DP (Revision 2) CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 37: Appendix

    CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 38: References

    FDT-Container, DOC040401OIxxEN, English, 2018-03. Hilscher Gesellschaft für Systemautomation mbH: Operation instruction manual, DTM for PROFIBUS DP Master devices, Configuration of Hilscher Master devices, DOC070401OIxxEN, English, 2018-04. Hilscher Gesellschaft für Systemautomation mbH: Operation instruction manual, DTM for Hilscher-PROFIBUS DP-Slave-devices, Configuration of Hilscher-Slave-devices, DOC091001OIxxEN, English, 2020-01.
  • Page 39 Electrostatics - Part 5-2: Protection of electronic components against electrostatic phenomena, User manual, (IEC TR 61340-5-2:2018), DIN IEC/ TR 61340-5-2 (VDE V 0300-5-2), English, 2019-04. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 40: Conventions In This Manual

    Indicates a hazardous situation, which if not avoided, may result in minor or moderate Injury. Indicates a property damage message. Table 28: Signal words CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 41: Legal Notes

    The manual delivered with the product shall apply. Under no circumstances shall Hilscher Gesellschaft für Systemautomation mbH be liable for direct, indirect, ancillary or subsequent damage, or for any loss of income, which may arise after use of the information contained herein.
  • Page 42 Appendix 42/49 Liability disclaimer The hardware and/or software was created and tested by Hilscher Gesellschaft für Systemautomation mbH with utmost care and is made available as is. No warranty can be assumed for the performance or flawlessness of the hardware and/or software under all application conditions and scenarios and the work results achieved by the user when using the hardware and/or software.
  • Page 43 Additional guarantees Although the hardware and software was developed and tested in-depth with greatest care, Hilscher Gesellschaft für Systemautomation mbH shall not assume any guarantee for the suitability thereof for any purpose that was not confirmed in writing. No guarantee can be granted whereby the...
  • Page 44 The customer hereby expressly acknowledges that this document contains trade secrets, information protected by copyright and other patent and ownership privileges as well as any related rights of Hilscher Gesellschaft für Systemautomation mbH. The customer agrees to treat as confidential all of the information made available to customer by Hilscher Gesellschaft für...
  • Page 45: Registered Trademarks

    * Die Master-Lizenz beinhaltet den Betrieb der PC-Karte cifX als Master sowie die Lizenz für die Konfigurationssoftware SYCON.net für das jeweilige cifX. CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 46 PROFIBUS interface (DSub socket connector, 9 pin), X201........ 26 Figure 7: Dimensions CIFX M3042100BM (Revision 2) ............35 Figure 8: AIFX-DP (Revision 2) ................... 36 CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 47 Technical data PROFIBUS DP Master ..............Table 26: Technical data PROFIBUS DP Slave ..............Table 27: Signs........................Table 28: Signal words ......................CIFX M3042100BM-DP\F | Hardware description and installation © Hilscher 2021 DOC210302UM01EN | Revision 1 | English | 2021-06 | Released | Public...
  • Page 48: Glossary

    Glossary 48/49 Glossary CIFX M3042100BM Communication interface in M.2 format and B+M key from Hilscher on the basis of the netX 100 communication controller Master Type of device that initiates and controls the communication on the netX networX on chip, Hilscher network communication controller. High integrated network controller with optimized system architecture for communication and maximum data transfer.
  • Page 49: Contacts

    Fax: +49 (0) 6190 9907-50 E-mail: info@hilscher.com Support Phone: +49 (0) 6190 9907-99 E-mail: de.support@hilscher.com SUBSIDIARIES China Japan Hilscher Systemautomation (Shanghai) Co. Ltd. Hilscher Japan KK 200010 Shanghai Tokyo, 160-0022 Phone: +86 (0) 21-6355-5161 Phone: +81 (0) 3-5362-0521 E-mail: info@hilscher.cn E-mail: info@hilscher.jp...

Table of Contents