Testing the NMS installation
UCC / Avaya one-X Speech - Avaya IP 600 / G3 / S8700 / S8300 E1 QSIG
7.0
TESTING THE NMS INSTALLATION
To verify the NMS board is working properly, use the trunkmon utility.
Run the digital trunk monitor utility - trunkmon
Trunkmon monitors alarms and gathers performance statistics for T1 trunks. A T1
alarm state is entered upon the presence of a Red, Yellow, or Blue alarm.
Status indicator LED's:
The AG4000 or AG4040 board has three (red, yellow, and green) indicators (LEDs)
for each trunk on the end of the bracket board. Each indicator is repeated four times
for each of the trunks for a total of 12 indicators (LEDs)
LED
Description
Red
Indicates loss of frame, loss of signal, or bit rate error.
Yellow
Indicates remote loss of frame or remote loss of signaling
multiframe.
Green
Indicates proper frame sync to the trunk: all requires framing has
been found. This LED is off if one or more of the following
conditions exist:
To run trunkmon, enter the following at the command prompt:
trunkmon –b<board>
If no T1 cables are connected to the AG4000 or AG4040 board, trunkmon shows a
loss of frame sync (Frame sync: No Frm) and an alarm state on all trunks. The red
alarm LED on the front panel should be lit for all trunks.
Connect a crossover cable between any two trunks on the AG Quad board. The
Frame Sync status should immediately change to OK and the green LEDs for those
trunks will light . The remote alarm (yellow) LEDs will light to show that the trunk
is indicating an alarm state to the other side. About 15 seconds after frame sync has
been acquired, both trunks leave the alarm state, trunkmon indicates none for the
alarm status and the red and yellow alarm LEDs go out. The frame sync (green)
LEDs remain lit.
The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1
-
All ones alarm (A1S)
-
Loss of frame
-
Loss of signaling multiframe
-
CRC errors (when board is configured for ESF)
17