Kaba RAC 4XT Installation Manual page 28

Ilco remote access controller
Hide thumbs Also See for RAC 4XT:
Table of Contents

Advertisement

6.0 Annex B Peripheral Wiring Diagrams
Figure 12: Relay Expansion Board Outputs Wiring
Note 1: Make sure all the wiring is complete, including the ribbon cable, before applying power to the RAC 4XT to ensure proper Relay
Note 2: The relay outputs are "fail safe". Accordingly, they are energized in their normal state and the relay status LED is ON. Upon power
Note 3: If the Fire Alarm Panel connection is not required, place a jumper wire between pin 3 and 4 of J18.
Note 4: In this example, the Normally Open relay outputs are used. Relay 2 controls access to Floor 7 and Relay 3 controls access to Floor
Note 5: For normal operation, set the relay override switches to the Off position (the relay status LED will be ON). Set the relay override
Figure 13: Power Adaptor to Power Supply PCB Wiring
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
5V
GND
12V 1
2
3
1
2
1
2
3
1
2
3
1
2
J1
J2
J3
RAC 4XT PCB
J14
J13
J12
1
2
3
1
2
3
1
2
5V GND 12V
1
2
3
1
2
Relay Override Switch
(See Note 5)
ELEVATOR CONTROL
PANEL
Floor 8 Input
Floor 7 Input
Floor 6 Input
Floor 5 Input
Floor 4 Input
Floor 3 Input
Floor 2 Input
Elevator
Floor 1 Input
Control Panel
Connections
(See Note 4)
Expansion Board functionality.
failure, or when the Fire alarm input is activated (when connected to a Fire Alarm panel), the relay state will change and access will
be automatically granted. The relay status written (NC or NO) is correct when unit is powered.
8. Actual wiring is specific to each application.
switch to ON to override the relay (the relay status LED will be OFF).
Power Adaptor
3
4
3
4
3
4
3
4
0
Power Supply
Page 27
Ribbon Cable
(See Note 1)
Note:
Expansion Board
drawing not to
scale