CAUTION:
!
Refer to the wiring label on the access
door, the wiring diagram & tables in Annex
A, or the detailed peripherals connections
in Annex B.
IMPORTANT:
Every wire must pass through a strain
relief as connected in step 4.
Follow the indications below for the
different peripherals being connected.
The actual items to connect will vary based
on the system configuration ordered.
NOTE: Refer to detailed wiring diagrams
provided in Annex B.
Electric strike or electromagnetic lock
1.
(locking device)
Refer to Annex B, Figure 4,5,6 & 7 for
detailed wiring.
IMPORTANT:
Kaba Ilco does not provide technical or
field support for 3rd party locking devices.
Please consult the device manufacturer
for support.
The following table indicates the maximum
recommended wire lengths that can be
used for typical locking devices, based on
wire gauge.
Locking
Typical
Device Type
Current
(A)
Electromag. Lock
0.28
Electric Strike
0.45
Double Electro. Lock 0.56
Other Devices
0.75
NOTE: The Maximum Recommended Wire
Length is the approximate wire length
that causes a 5% voltage loss in the
wire, using a 12-volt locking device at
the rated current included.
CAUTION:
!
This table is for reference only. Actual
wiring requirements for specific devices
may differ. Always follow the locking device
manufacturer's wiring recommendations
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
Maximum Recommended
Wire Length,
One-Way (feet)
AWG
AWG
AWG
AWG
18
16
14
12
170
265
425
675
105
165
265
420
90
145
230
365
65
100
160
250
Page 13
as well as local building codes.
1.1 Install and route a 2-conductor cable from
the controller PCB to the desired location
of the electric strike or electromagnetic
lock.
1.2 If installing an electric strike, install the
diode across the terminals of the locking
device,
using
the
provided in the hardware bag if needed.
IMPORTANT:
Do not reverse the diode polarity as
indicated on the wiring diagram.
CAUTION:
To prevent a possible short, the diode
must not be in contact with electric strike.
If required cut the diode ends shorter.
1.3 Mount
the
locking
desired
location
per
manufacturer's
connections between locking device and
controller PCB refer to Annex A, Table 3.
2.
Request to Exit button (REX)
Refer to Annex B, Figure 8 for detailed
wiring.
Mount the device at the desired location
and run a 2-conductor cable from the
request to exit button to controller PCB
connector J8, pins 3 & 4. Connect as per
Annex A, Table 3.
3.
Remote Unlock button
Refer to Annex B, Figure 8 for detailed
wiring.
Mount the device at the desired location
and run a 2-conductor cable from the
remote unlock button to the controller
PCB connector J8, pins 1 & 2. Connect as
per Annex A, Table 3.
4.
Motion Detector
Refer to Annex B, Figure 9 for detailed
wiring.
Mount the device at the desired location
and run a 4-conductor cable from the
motion detector relay's terminal block to
controller PCB connector J8, pins 3 & 4.
crimp
connectors
device
in
the
and
connect
as
instructions.
For

Advertisement

Table of Contents
loading

Table of Contents