5.0

Settings and Operation

5.1 Testing

1.
Connect the AC power adaptor and / or
turn on the AC current.
2.
Verify that the Power Status LED on the
access door is ON.
3.
If equipped, verify that the Battery Status
LED on the access door is ON.
NOTE: Battery status LED may be off if the
battery is completely discharged or
if the connections are reversed. A
properly connected battery may take
up to 12 hours to charge and the LED
to turn on.
4.
Verify that the Func1 (D45) & Func2
(D46) LEDs on the controller PCB blink
continuously.
5.
Activate the Bypass switch (SW3) on the
controller PCB.
6.
Verify that the locking device is activated.
If it is not activated verify that the Fire
Alarm input is properly connected or that
a jumper wire is connected on J18 pins 3
& 4.
7.
Deactivate the bypass switch (SW3) on
the controller PCB.
8.
As per the FDU or ATLAS manuals make a
test card and use it on the card reader(s)
connected. If the RAC 4XT has never
been initialized, the door will unlock. The
unlock time will correspond to the delay
set by the DIP switches as per Annex A,
Table 2.
9.
If a REX button is connected, press it and
verify that the door unlocks.
10. If a Remote Unlock button is connected,
press it and verify that the door unlocks.
11. If a Motion Detector is connected, pass in
front of it to verify that the door unlocks.
12. If the RAC 4XT is connected to a fire panel
verify that the electromagnetic lock or a
fail-safe electric strike is deactivated when
the fire alarm is active (open input).
13. If a battery back-up is equipped, when
fully charged remove the main AC power
adaptor and verify proper RAC 4XT
operation.
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14

5.2 Hotel ID Initialization

1.
Create an initialization keycard with the
hotel's FDU or ATLAS system.
2.
Use
keycard on the connected card reader(s).
Depending on the type of card reader
the LED(s) will react as indicated below.
Additionally for all situations the controller
PCB can be verified to ensure that LED
D41 is ON.
Swipe card reader:
The red and green LEDs should flash in
sequence: red & green once, followed by
green once.
Insert card reader:
The red and green LEDs should flash in
sequence: red & green once, followed by
green once.
Contactless card reader:
The green LED on the reader should flash
in sequence: rapid green twice, followed
by normal green once.

5.3 Hotel ID Re-initialization

In the event the Hotel ID of the premises is
changed or a problem is suspected with the
current configuration, the RAC 4XT will need
to re-initialize its Hotel ID.
1.
NOTE down the current delay setting as
indicated on SW2 of the controller PCB.
2.
Set the DIP switches on SW2 of the
controller PCB to CFG #16 (OFF, OFF,
OFF, OFF) as per Annex A, Table 2.
3.
Verify that the initialization LED (D41) is
OFF.
4.
Set the DIP switch positions back to the
chosen delay settings as NOTEd above,
or select a new setting as per Annex A,
Table 2.
5.
Follow the steps as per section 5.2 "Hotel
ID Initialization" above.