Kaba RAC 4XT Installation Manual page 26

Ilco remote access controller
Hide thumbs Also See for RAC 4XT:
Table of Contents

Advertisement

6.0 Annex B Peripheral Wiring Diagrams
Figure 8: Request to Exit (REX) or Remote Unlock Button Wiring
5V
GND
1
1
5V GND 12V
The Remote Unlock input (J8, pins 1 & 2) unlocks the door only for the
delay set by the DIP switches, EVEN if the button stays pressed.
The REX input (J8, pins 3 & 4) unlocks the door for as long as the button
is pressed PLUS the delay set by the DIP switches.
The Exit Button can be connected to either the Remote Unlock or the REX
input, depending on the required functionality. In both cases, the wires
should be connected to the Normally Open contact of the Exit button.
In general, a Motion Detector or a maual override should be connected to
the REX input (J8, pins 3 & 4).
Figure 9: Motion Detector Wiring
Black Wire
Power Supply
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
12V 1
2
3
1
2
3
4
2
3
1
2
3
1
2
3
4
J1
J2
J3
RAC 4XT PCB
J14
J13
J12
2
3
1
2
3
1
2
3
4
1
2
3
1
2
3
4
5V
Red Wire
NOTE:
If the Egress reader is not used on RAC 4XT, the
motion detector can be powered from J14, pin 3 (12V)
and J14, pin 2 (GND).
GND
12V 1
2
3
1
2
3
4
1
2
3
1
2
3
1
2
3
4
J1
J2
J3
RAC 4XT PCB
J14
J13
J12
1
2
3
1
2
3
1
2
3
4
5V GND 12V
1
2
3
1
2
3
4
Page 25
REX
Remote
Unlock
EXIT
EXIT
NO COM NC
NO COM NC
Motion
Detector

Advertisement

Table of Contents
loading

Table of Contents