Function Unit Commands
FU
(Function Unit)
Reader
final
public (B)
2008-01-07
H30701-3e-ID-B

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic OBID i-scan ID ISC.ANT.MUX

  • Page 1 ® MANUAL OBID i-scan Communication FU Communication Function Unit Function Unit Commands (Function Unit) Reader final public (B) 2008-01-07 H30701-3e-ID-B...
  • Page 2 GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
  • Page 3: Table Of Contents

    3.2.1. [0xC0]: Get Firmware Version ..................18 3.2.2. [0xC1]: CPU-Reset ......................19 3.2.3. [0xC2]: Set Capacities ....................19 3.2.4. [0xC3]: Get Antenna-Values ..................20 3.2.5. [0xC4]: Set Outputs .....................21 3.2.6. [0xC5]: ReTuning......................22 3.2.7. [0xC6]: Start-Tuning.....................22 3.2.8. [0xC8]: Store Settings....................23 FEIG ELECTRONIC GmbH Page 3 of 27 H30701-3e-ID-B...
  • Page 4 3.2.9. [0xC9]: Detect ......................23 3.2.10. [0xCA]: Set Address ....................24 3.2.11. [0xCB]: Set Mode......................24 APPENDIX APPENDIX A: Index STATUS ....................25 APPENDIX B: Index Control Bytes ..................26 APPENDIX C: Protocol on Host Interface ................27 FEIG ELECTRONIC GmbH Page 4 of 27 H30701-3e-ID-B...
  • Page 5 It is possible to connect multiple function units an a cascading arrangement. (see Figure 2). Function Unit 2 Function Host Reader Unit 1 Function Function Unit 3 Unit 4 Figure 2: System with more than one Function Unit FEIG ELECTRONIC GmbH Page 5 of 27 H30701-3e-ID-B...
  • Page 6 Tuner 1 ponder (DAT) Host Reader Multiplexer (MUX) Antenna Trans- Tuner 2 ponder (DAT) Figure 3: System with three Function Units see 2. Antenna Multiplexer ID ISC.ANT.MUX see 3. Antenna Tuner ID ISC.DAT FEIG ELECTRONIC GmbH Page 6 of 27 H30701-3e-ID-B...
  • Page 7: Antenna Multiplexer Id Isc.ant.mux

    Here the multiplexers must be addressed for controlling the respective units. Addressing of the multiplexers is described in greater detail in section 2.1.4. Multiplexer Address Setting. Below are several examples which demonstrate the possibilities for a multiplexer. FEIG ELECTRONIC GmbH Page 7 of 27 H30701-3e-ID-B...
  • Page 8: Configuration Using One Input

    The protocols always contain the address of the multiplexer to be activated. This means that even when using only one multiplexer, it must be addressed also (see 2.1.4. Multiplexer Address Setting). FEIG ELECTRONIC GmbH Page 8 of 27 H30701-3e-ID-B...
  • Page 9: Configuration Using Both Inputs

    The protocols always contain the address of the multiplexer to be activated. This means that even when using only one multiplexer, it must be addressed also (see 2.1.4. Multiplexer Address Setting). FEIG ELECTRONIC GmbH Page 9 of 27 H30701-3e-ID-B...
  • Page 10: Configuration With Cascaded Multiplexers

    It is not possible to activate all multiplexers at the same time. The protocols always contain the address of the multiplexer to be activated (see 2.1.4. Multiplexer Address Setting). FEIG ELECTRONIC GmbH Page 10 of 27 H30701-3e-ID-B...
  • Page 11: Multiplexer Address Setting

    Since only one multiplexer output can be active at a time, it is also possible to communicate with only one multiplexer on a level. For DIP switch settings see installation guide for ID ISC.ANT.MUX (M30201-xde-ID-B). FEIG ELECTRONIC GmbH Page 11 of 27 H30701-3e-ID-B...
  • Page 12: Commands For Mux Control

    MUX firmware revision main revision sub revision 8 bits 8 bits SW-Type: Software-Type: 0x0A ID ISCANTMUX (10) HW-Rev: Hardware-Revision DIP: DIP switch setting on multiplexer 2.1.4. Multiplexer Address Setting APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 12 of 27 H30701-3e-ID-B...
  • Page 13: 0Xde]: Cpu-Reset

    STATUS 0x11 (Parameter Range Error). A setting of 0x00 overwrites the current channel setting. 2.1.4. Multiplexer Address Setting APPENDIX A: Index STATUS 2.1.4. Multiplexer Address Setting APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 13 of 27 H30701-3e-ID-B...
  • Page 14: 0Xdc]: Detect

    This protocol is used to query the address and DIP switch setting, i.e., the set mode of the multiplexer. Host → MUX Data [0xDC] MUX-Adr 0x02 8 bits 0xFE 8 bits Host ← MUX Data STATUS 0x00 8 bits 2.1.4. Multiplexer Address Setting APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 14 of 27 H30701-3e-ID-B...
  • Page 15: Antenna Tuner Id Isc.dat

    (DAT) antenna loop Figure 10: antenna tuner 3.1.1. Configuration with one Antenna Figure 11 shows a configuration using one antenna. Figure 11: configuration using one antenna Reader FEIG ELECTRONIC GmbH Page 15 of 27 H30701-3e-ID-B...
  • Page 16: Configuration With Multiple Antennas

    Reader through a power splitter. The antenna tuners have their own addresses. Adr. 1 Adr. 2 Power Splitter Reader Figure 12: Configuration with a Power Splitter FEIG ELECTRONIC GmbH Page 16 of 27 H30701-3e-ID-B...
  • Page 17: Configuration With A Multiplexer

    Figure 13: Configuration with a multiplexer 3.1.3. Setting Antenna Tuner Addresses The address is set using „Set Address“(see 3.2.10. [0xCA]: Set Address). The factory default address setting for the antenna tuners is 1. FEIG ELECTRONIC GmbH Page 17 of 27 H30701-3e-ID-B...
  • Page 18: Commands For Tuner Control

    24 bits SW-Rev: Revision von Tuner-Firmware main revison sub revision 8 bits 8 bits SW-Type: Software-Type: 0x0B ID ISCDAT (11) HW-Rev: Hardware-Revision 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 18 of 27 H30701-3e-ID-B...
  • Page 19: 0Xc1]: Cpu-Reset

    STATUS 0x11 (Parameter Range Error). A setting of 0x00 overwrites the current capacity setting. 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 19 of 27 H30701-3e-ID-B...
  • Page 20: 0Xc3]: Get Antenna-Values

    Difference between R and R mess most significant least significant 8 bits 8 bits Phi: Value of Phase ϕ (0x00 – 0x5A) 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 20 of 27 H30701-3e-ID-B...
  • Page 21: 0Xc4]: Set Outputs

    It is possible to activate maximal two outputs at the same time or else the protocoll will be rejected and acknowledged with STATUS 0x11 (Parameter Range Error). 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 21 of 27 H30701-3e-ID-B...
  • Page 22: 0Xc5]: Retuning

    8 bits Host ← Tuner Data STATUS 0x00 8 bits 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 22 of 27 H30701-3e-ID-B...
  • Page 23: 0Xc8]: Store Settings

    8 bits Host ← Tuner Data STATUS 0x00 8 bits 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 23 of 27 H30701-3e-ID-B...
  • Page 24: 0Xca]: Set Address

    6 min! Reset to the current Mode after a CPU-Reset [0xC1]) 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS 3.1. System Description of the Antenna Tuner APPENDIX A: Index STATUS FEIG ELECTRONIC GmbH Page 24 of 27 H30701-3e-ID-B...
  • Page 25: Appendix

    APPENDIX A: Index STATUS Hex-Value Status 0x00 0x11 Parameter Range Error the value of the parameter is exceed 0x84 RF-Warning Multiplexer The impedance at the switched output is to low wrong cable length FEIG ELECTRONIC GmbH Page 25 of 27 H30701-3e-ID-B...
  • Page 26: Appendix B: Index Control Bytes

    3.2.9. [0xC9]: Detect [0xCA] 3.2.10. [0xCA]: Set Address [0xCB] 3.2.11. [0xCB]: Set Mode Multiplexer [0xDC] 2.2.4. [0xDC]: Detect [0xDD] 2.2.3. [0xDD]: Select Channel [0xDE] 2.2.2. [0xDE]: CPU-Reset [0xDF] 2.2.1. [0xDF]: Get Firmware Version FEIG ELECTRONIC GmbH Page 26 of 27 H30701-3e-ID-B...
  • Page 27: Appendix C: Protocol On Host Interface

    FEFU_DAT_ StoreSettings( int iReaderHnd, UCHAR ucReaderBusAdr, UCHAR ucDatAdr) • int FEFU_DAT_ SetAddress( int iReaderHnd, UCHAR ucReaderBusAdr, UCHAR ucDatAdr, UCHAR ucNewDatAdr) • int FEFU_DAT_SetMode ( int iReaderHnd, UCHAR ucReaderBusAdr, UCHAR ucDatAdr, UCHAR ucMode) See manual ID FEFU (H30801-xe-ID-B.doc) FEIG ELECTRONIC GmbH Page 27 of 27 H30701-3e-ID-B...