Table of Contents

Advertisement

IDENTIFICATION
INSTALLATION
ID LRU500i-BD / ID LRU500i-PoE
(EU: 5117.000.00 / 5117.001.00; FCC: 5117.000.10 / 5117.001.10)
M81210-2e-ID-B

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID LRU500i-BD Series

  • Page 1 IDENTIFICATION INSTALLATION ID LRU500i-BD / ID LRU500i-PoE (EU: 5117.000.00 / 5117.001.00; FCC: 5117.000.10 / 5117.001.10) M81210-2e-ID-B...
  • Page 2 Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
  • Page 3: Table Of Contents

    IDENTIFICATION ID LRU500i Contents Contents Contents Safety Instructions Performance Features of ID LRU500i Performance Features ....................... 6 Available Reader Types ....................6 Scope of Delivery ID LRU500i-BD ........................7 ID LRU500i-PoE ......................... 7 Installation Terminals Antenna Connection ......................13 Power Supply ........................14 5.2.1 Power Supply via Connector X2 ................
  • Page 4 IDENTIFICATION ID LRU500i Contents Status LEDs ........................26 Push Button T1 ........................ 26 DIP Switches S1 ....................... 27 Buzzer ..........................27 Reader Power Adjustment ....................27 Technical Data Radio Approvals Europe (CE) ........................30 USA (FCC) and Canada (IC) .................... 31 8.2.1 USA (FCC) and Canada (IC) Warning Notices .............
  • Page 5: Safety Instructions

    IDENTIFICATION ID LRU500i 1 Safety Instructions 1 Safety Instructions Safety Instructions ► The device may only be used for the intended purpose designed by the manufacturer. ► The manual should be conveniently kept available at all times for each user. ►...
  • Page 6: Performance Features Of Id Lru500I

    IDENTIFICATION ID LRU500i 2 Performance Features 2 Performance Features of ID LRU500i Performance Features 2.1 Performance Features With its compact size, its weather-resistant housing, a read range of 8 to 10 m and the circular-polarized antenna supporting any transponder orientation, the UHF Compact Reader ID LRU500i is ideally suited to provide efficient and secure vehicle access control.
  • Page 7: Scope Of Delivery

    IDENTIFICATION ID LRU500i 3 Scope of Delivery 3 Scope of Delivery Scope of Delivery 3.1 ID LRU500i-BD The scope of delivery includes following components: 1 x ID LRU500i-BD 1 x ESKV 20 M20 cable gland for cable ∅ 6–13 mm; for USB •...
  • Page 8: Installation

    (see Fig. 4), that should be fixed with screw locking varnish, and e.g. a wire rope. The suitable accessory ID ANT.UEB-A can be purchased from FEIG ELECTRONIC. Fig. 1: Dimensional drawing – back view...
  • Page 9: Fig. 2: Dimensional Drawing - Side View

    IDENTIFICATION ID LRU500i 4 Installation Fig. 2: Dimensional drawing – side view Installation Page 9 of 35...
  • Page 10: Fig. 3: Dimensional Drawing - Top View: Opened Housing

    IDENTIFICATION ID LRU500i 4 Installation Fig. 3: Dimensional drawing – top view: opened housing Installation Page 10 of 35...
  • Page 11: Fig. 4: Secondary Protection Via Eye Bolt

    IDENTIFICATION ID LRU500i 4 Installation Fig. 4: Secondary protection via eye bolt  NOTE: FEIG ELECTRONIC GmbH strongly recommends to secure the reader against falling by means of an eye bolt to prevent damage. Installation Page 11 of 35...
  • Page 12: Terminals

    IDENTIFICATION ID LRU500i 5 Terminals 5 Terminals Terminals The cable connections are located on the lower side of the reader. Fig. 5 shows the arrangement of the connectors and Table 1 gives an overview on the available connectors and interfaces. Table 2 lists the available operating and display elements.
  • Page 13: Antenna Connection

    IDENTIFICATION ID LRU500i 5 Terminals 5.1 Antenna Connection The TNC socket for connecting the external antenna is located on the lower side of the reader. The maximum tightening torque for the TNC sockets is 0.69 Nm (6.11 lbf in). For the power supply of external components, e.g. the UHF antenna multiplexer ID ISC.ANT.UMUX, it is possible to apply the V voltage of the reader (24 V DC / max.
  • Page 14: Power Supply

    IDENTIFICATION ID LRU500i 5 Terminals 5.2 Power Supply 5.2.1 Power Supply via Connector X2 The supply voltage of 12–24 V DC has to be connected to terminal X2. Fig. 7: Connector X2 pin assignment for power supply Pin Number at Abbreviation Description Connector X2...
  • Page 15: Power Supply Via Poe (Power Over Ethernet)

    IDENTIFICATION ID LRU500i 5 Terminals 5.2.2 Power Supply via PoE (Power over Ethernet) Optional the reader (only ID LRU500i-PoE) can be powered via the Ethernet interface on X1 with the use of a PoE „Power over Ethernet“ power supply according to IEEE802.3at*, Class4 (30/25,5Watt). The DC supply can be achieved via the free pins 4, 5 and 7, 8 (Midspan-Power).
  • Page 16: Ethernet Interface On Connector X1

    IDENTIFICATION ID LRU500i 5 Terminals 5.3 Ethernet Interface on Connector X1 The reader has an integrated 10/100 base-T network port for an RJ-45. Connection is made on X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling STP CAT5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps.
  • Page 17: Rs485 Interface On Connector X3

    IDENTIFICATION ID LRU500i 5 Terminals 5.4 RS485 Interface on Connector X3 The RS485 interface is connected on X3. The transmission parameters can be configured via software protocol. Fig. 10: RS485 interface pin assignment on X3 Pin Number at Pin Assignment Connector X3 RS485 B+ RS485 A–...
  • Page 18: Data-Clock Interface On Connector X3

    IDENTIFICATION ID LRU500i 5 Terminals 5.5 Data-Clock Interface on Connector X3 The data-clock (Wiegand) interface is connected via terminal X3. Fig. 11: Pin assignment Data-Clock (Wiegand) interface on X3 Pin Number at Pin Assignment Connector X4 Wiegand D1 Wiegand D0 Table 8: Pin Assignment Data-Clock (Wiegand) Interface ...
  • Page 19: Digital Outputs On Connector X4

    IDENTIFICATION ID LRU500i 5 Terminals 5.6 Digital Outputs on Connector X4 There are 2 digital outputs available on terminal X4 (type LRU500i-BD none). The transistor connection, collector and emitter, of the optocoupler output is galvanically isolated from the reader electronic and routed to the outside at terminal X4 without internal additional circuitry.
  • Page 20: Relay Outputs On Connector X4

    IDENTIFICATION ID LRU500i 5 Terminals CAUTION: • The outputs are designed for an input voltage of 12-24 V DC and an input current of max. 20 mA. • Polarity reversal or overload of the outputs leads to their destruction! • The output is only intended for switching resistive loads.
  • Page 21: Digital Inputs On Connector X5

    IDENTIFICATION ID LRU500i 5 Terminals Fig. 16: Connector X4 pin assignment for relay outputs (version LRU500i-BD) CAUTION: • The relay outputs are designed for max. 24 V DC / 2 A continuous load. • The maximum switching current must not exceed 1 A. The relay outputs are intended for switching resistive loads only.
  • Page 22: Table 11: Pin Assignment X5 (Digital Inputs)

    IDENTIFICATION ID LRU500i 5 Terminals Pin Number at Pin Assignment Connector X5 OPTO2-IN – OPTO2-IN + OPTO1-IN – OPTO1-IN + Table 11: Pin Assignment X5 (digital inputs) Fig. 18: External wiring of the digital inputs The external resistor Rext is optional. When wiring the reader, make sure that the input voltage is at least 10.5 V.
  • Page 23: Usb Mini Interface On Connector X6

    IDENTIFICATION ID LRU500i 5 Terminals 5.9 USB Mini Interface on Connector X6 The reader is equipped with an integrated USB on-the-go interface. This can be used either to connect the reader to a host system or, by means of a special on-the-go adapter cable, for connection of a USB memory stick to the reader.
  • Page 24: Storing The Reader Configuration On A Usb Flash Drive

    IDENTIFICATION ID LRU500i 5 Terminals In addition, the files ACTION.LOG and SERVICE.LOG with further information for service and maintenance for the devices will be generated and stored on the USB flash drive. The function of the CONFIG.INI is described in the following chapter. After plugging in the USB flash drive the green and red status LEDs will light up permanently.
  • Page 25 IDENTIFICATION ID LRU500i 5 Terminals It must be ensured that no configuration page (CFG page) is password protected in the reader. If configuration pages are password protected, the configuration file will not be copied onto the reader. This also applies if individual configuration parameters contain values out of the permissible range. After successful completion of the USB actions the red status LED will go out and the green status LED will start flashing again.
  • Page 26: Operating And Display Elements

    IDENTIFICATION ID LRU500i 6 Operating and Display Elements 6 Operating and Display Elements Operating and Display Elements 6.1 Status LEDs The status LEDs are located under the push button T1 and the DIP switches S1. Reader status LEDs Res. Warning Description (yellow) (red)
  • Page 27: Dip Switches S1

    The output power depends on the antenna gain. For calculating the reader output power the Excel file “Calc-RF-Power.xls” is available from FEIG ELECTRONIC GmbH. If a circular polarized antenna is used the antenna gain [dBic] can be reduced by 3 dB. If using a linear polarized antenna the max.
  • Page 28: Technical Data

    IDENTIFICATION ID LRU500i 7 Technical Data 7 Technical Data Technical Data Mechanical Data Housing Plastic (ASA-PC) Aluminum Dimension (W x H x D) 290 mm x 290 mm x 100 mm (11.4“ x 11.4“ x 3.9“) Weight 2800 g Mounting VESA FDMI MIS-D 100 mm x 100 mm Protection Class IP 65...
  • Page 29 IDENTIFICATION ID LRU500i 7 Technical Data Further Features Anti-Collision, output of RSSI values and phase angle, battery-assisted Real Time Clock, supports encrypted transponder communication, Secure Key Storage, Config Cloning Function Environmental Conditions Temperature Range -25 °C to 55 °C • Operation -25 °C to 85 °C Storage...
  • Page 30: Radio Approvals

    8 Radio Approvals Radio Approvals 8.1 Europe (CE) Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID LRU500i is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html...
  • Page 31: Usa (Fcc) And Canada (Ic)

    United States / Canada. The system is intended for industrial and commercial use and requires professional installation. The device and the software required for commissioning and operation are only available from FEIG ELECTRONIC or its distributors. Installation, commissioning, configuration and operation require qualified knowledge of high-frequency and RFID technology due to its complexity.
  • Page 32: Label Information

    IDENTIFICATION ID LRU500i 8 Radio Approvals 8.2.3 Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID: PJMLRU500i Contains IC: 6633A-LRU500i 8.2.4 Antennas Approved in the USA (FCC) and Canada (IC) This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with maximum permission gain and required antenna impedance for each antenna type indicated.
  • Page 33: Annex A: Accessories

    IDENTIFICATION ID LRU500i Annex A: Accessories Annex A: Accessories Accessories For the ID LRU500i following optional accessories are available: Order Number Article Description 24 V Power Supply Unit; Supply Cable available separately 2557.000.00 ID NET.24V-B for EU, GB and US (not included) 2558.000.00 ID CAB.NET.24V-B-EU Power Supply Unit Cable with continental Europe plug...
  • Page 34: List Of Tables

    IDENTIFICATION ID LRU500i List of Tables List of Tables List of Tables Table 1: Connection Terminals ........................12 Table 2: Operating and Display Elements ....................... 12 Table 3: Pin assignment for power supply ....................... 14 Table 4: Validation procedures for external wiring of the power supply ............14 Table 5: Max.
  • Page 35: List Of Figures

    IDENTIFICATION ID LRU500i List of Figures List of Figures List of Figures Fig. 1: Dimensional drawing – back view ......................8 Fig. 2: Dimensional drawing – side view ......................9 Fig. 3: Dimensional drawing – top view: opened housing ................10 Fig.

Table of Contents