HTC Athena Service Manual page 69

Table of Contents

Advertisement

Doc. Title
Leakage current measurement when Backlight off/Sleep mode
XI. Tap Start->System->Backlight.
XII. Adjust the backlight level to 0% and
checks the current from current
meter.
[Note1]
XIII. Press power button to initial device
enter sleep mode and checks the
current from current meter.
[Note1]: 106mA (
[Note2]: 3mA (
I.
If current consumption test PASS when UUT in Flight and Sleep mode, it means that
the M/B works normal.
II.
If current consumption test FAIL when UUT in Flight or Sleep mode, it means that the
M/B works abnormal, please replace M/B and re-test again.
HTC CONFIDENTIAL
宏達國際電子股份有限公司
High Tech Computer, Corp.
.
Athena Service Manual
[Note2]
Spec ≦ 106mA).
Spec ≦ 3mA).
Conclusion
Doc. No.
DOC-00026040
Issued Date
2007/2/15
Revised Date
Page
69 of 102
REV.
A02